SMARTSCAN 5K8 SERIES LIGHT CURTAIN
12
CD401/130711
INSTALLATION SHEET EXPLAINED
Please note that the Installation Sheet Explained documents are periodically updated. The product Installation Sheets
supplied with the product should be referenced first for current installation information.
Power supply -
Use a regulated 24V DC, 2A ƒ10%. Protect the +24V
input with a 1.5A fuse. Connect the power supply to cable B as follows: The
red (RD) wire to +24V DC and the black (BK) wire to L- V DC. Connect the
screen to ground.
All input and output connections from the Smartscan 5K8 Series are via a plug
connected into the Receiver (RX) head – Cable B (User).
Note:
Prior to initial power up of the light curtain check the following:
Red (RD) / blue (BU) wire ‘
mute enable
’, is connected to 0V DC
via a 3
rd
mute signal, e.g. conveyor run.
EDM. Is connected across the N/C contact of the FSD. If not used
link the green (GN) wire to the green (GN) / red (RD) wire.
Note:
Prior to initial power up of the light curtain check the following:
If the Smartscan system is connected directly to a 24V DC source
supplied by the user, it must be emphasised that the supply should be
regulated and suppressed to prevent transient voltages and other forms of
electrical interference from affecting correct operation of the Smartscan
equipment.