iSmartATF 501 Auto Transmission Cleaner and Fluid Exchanger User’s Manual
8
2. Filling liquid
2.1 Filling detergent
When you are ready to perform the circulating cleaning
for auto transmission, please fill proper amount of
detergent into the detergent container (please refer to
Fig.3).
2.2 Adding new oil
When you are ready to perform the ATF exchange
operation, please fill new fluid into the new fluid tank
from the fluid filling port (please refer to Fig.3).
3. Circulating cleaning
3.1Fill detergent to auto transmission
1) Select the function of “Add ATF detergent” in main
menu, and set the amount of the detergent to be filled
(the setting range: 0.00-0.50 L). Refer to Fig.9.
Fig.9
Note: Fill detergent before need to calibrate cleaning
speed (see "cleaning speed" sensor calibration content).
2) Input the amount to be filled. The default value of the
unit is 0.20L and the maximum value is 0.50L. Press
ENTER key after the amount to be filled is confirmed,
the detergent filled inside the detergent container will
be pumped into the hose.
Fig.10
3)
After the filling operation is finished, the system will
automatically pop up print menu. Press ENTER key
select print, press RETURN key to cancel printing.
Refer to Fig.11
Fig.11
4) Print is completed or cancelled, will pop up 10
minutes cycle cleaning countdown. Refer to Fig.12.
Fig.12
3.2 Circulating cleaning
After the detergent is filled into the hose, start the
engine and the fluid will circulate from the iSmartATF
501 pipelines to the Automatic Transmission. In order to
speed up the circulating process, it is advisable to
perform the gear-shift operation (The running time for
each gear-shift should be kept for about 1 minute,
which depends on actual situation. When the vehicle
engine is running with high-speed, the speed should be
more than 60 km/h to ensure the effect of cleaning).
The circulating cleaning option is not set in iSmartATF
501 main menu. When the hoses are well connected,
start the vehicle engine and the unit will enter the
circulating process automatically. If the cleaning
circulation operation is needed for a long period of time,
please turn off the power supply of iSmartATF 501.
3.3 Finish circulating cleaning
After the circulating cleaning operation has been lasted
for more than 10 minutes, please turn off the engine to
end the circulating cleaning process.
4. ATF exchange
When different kind of fluid is used or the unit is stored
for a long time, about 0.5L new fluid should be filled into
new fluid tank. With the way of emptying the new fluid
tank, clean the fluid hoses and drain the air bubbles out
from the unit.