4
WIRING –
(Check off box when complete)
** Refer to the Appendix for the following connections **
Power –
(Sheet 3: Machine Room connections)
Connect main line power to terminal block L1/L2/L3.
Connect the ground wire to the yellow/green terminal block next
to L1-L3.
Brake –
(Sheet 5: Brakes)
Connect the main brake wiring to terminals K1 / K2 and the
secondary brake wiring to terminals J1 / J2 located on the terminal
block between the M contactor and the L1~L3 terminal blocks.
Jump EB to the terminal listed in the Construction box located on
“Sheet 01 – Getting Started” and connect either the rope gripper
or sheave brake to EBR (if installed).
Motor Leads
Connect motor leads to the M contactor at T1/T2/T3.
Encoder Cable –
(Sheet 4: Drive and Motor)
Connect the encoder cable to terminal block TB1 located under the
lower cover to terminals 1, 2, 3, 4, 5, 17, & 18 (see table below).
Proximity Sensor –
(Sheet 4: Drive and Motor)
Install the proximity sensor per the instructions in the Axial Flux
manual TM7354 - (pp. 6-8).
Connect the proximity sensor to terminal block TB1 located under
the lower cover to terminals 5, 17, 18, & 19 (see table below).