OPERATION 

(Check off box when complete)

 

Run the car and verify the following:

 

No Faults 

 

Make sure the car is moving without triggering a fault either 
on the Smartrise SRU or the drive. If the SRU board displays a 
“Drive Fault” on the SRU, look at the drive to see what the 
fault is. The most common fault is “Encoder Flt”.  

o

 

Go  to  “

Troubleshooting  –  Drive  Fault  /  Encoder  Flt

”  for 

corrective actions. 

Proper Direction 

 

Make  sure  the  car  is  moving  in  the  same  direction  as  the 
control switch on the Run Bug. 

o

 

Go to “

Troubleshooting – Wrong Direction

” for corrective 

actions. 

At Speed 

 

Make  sure  that  the  car  is  moving  at  the  proper  inspection 
speed (approx. 50 FPM). 

o

 

Go to “

Troubleshooting – Car Moving Too Slow or Rough

” 

for corrective actions. 

Under Control 

 

Make sure that the car is moving under full control. The car 
should stop when commanded from the Run Bug. Verify that 
the car runs with no faults for 10 seconds or more. 

o

 

Go to “

Troubleshooting – Brake Not Lifting

” for corrective 

actions. 

 

 

Summary of Contents for Magnetek HPV900AF

Page 1: ...DRIVE STARTUP MANUAL Magnetek HPV900AF Drive PM Motor Installation www smartrise us 2601 Fair Oaks Blvd Sacramento CA 95864 916 457 5129...

Page 2: ...AMETER LOCATION REFERENCE ADJUST A0 DRIVE A1 Encoder Pulses Follow procedure in Axial Flux manual Pg 9 POWER CONVERT A4 Input L L Volts MOTOR A5 Rated Mtr Power Kw Rated Mtr Volts VAC Rated Exit Freq...

Page 3: ...side of the incoming water main To a grounding rod that has been driven into the pit flooring The controller has a common ground bus terminal connection All grounds need to land at this common point i...

Page 4: ...l blocks Jump EB to the terminal listed in the Construction box located on Sheet 01 Getting Started and connect either the rope gripper or sheave brake to EBR if installed Motor Leads Connect motor le...

Page 5: ...ween M24 and the IOs listed on Sheet 1 Getting Started Construction Install jumpers between M24 any additional IO s if required Pre Transfer Emergency Power Governor IMPORTANT REMOVE FACTORY WIRES ON...

Page 6: ...Check off box when complete Toggle the Inspection Normal switch to the INSP position Set BYPASS TERM LIMITS to YES o On the Smartrise Machine Room controller board press the Left Arrow ESC button seve...

Page 7: ...to YES o Use the RIGHT Arrow key and move the asterix under the word SAVE and press enter o Hit the LEFT Arrow ESC button several times to get to the MAIN SCREEN Verify the LCD displays Construction M...

Page 8: ...to YES but DON T PRESS THE ENTER BUTTON YET Press and hold the M contactor button in Press the Enter button on the drive to start the alignment ENCODER ALIGNMENT NON ROTATIONAL Check off box when comp...

Page 9: ...PARAMETER DESCRIPTION CHOICES AUTOTUNE SELECT ALLOW AUTOTUNE TO RUN DISABLE ON RUN YES ROTOR ALIGN U10 PARAMETER DESCRIPTION CHOICES ALIGNMENT ALLOW ALIGNMENT TO BE PERFORMED ENABLE DISABLE BEGIN ALIG...

Page 10: ...ions Proper Direction Make sure the car is moving in the same direction as the control switch on the Run Bug o Go to Troubleshooting Wrong Direction for corrective actions At Speed Make sure that the...

Page 11: ...the terminal listed on Sheet 01 Getting Started If it has the proper voltage check the following a During a run command check for DC voltage between points K1 K2 and J1 J2 Verify the voltages are als...

Page 12: ...5 that conflicts with drive software 1 Unplug the CAT5 cable from the DRIVE port on the machine room SRU board This will restore access to the HPV LCD screen 2 Go to A5 Motor Parameters Motor Poles an...

Page 13: ...13 APPENDIX Terminal Locations Encoder wiring terminals GND terminals Main Line terminals L1 L2 L3 Motor terminals T1 T2 T3 Brake terminal block J1 J2 K1 K2 Terminal TB1 J1 J2...

Reviews: