13
B
EL
L
开门防撞感应器
关门防撞感应器
NO
COM
GND
+24V
24.
开门防撞
22.
GND
22.
GND
20.
+24V
NO
COM
GND
+24V
23.
关门防撞
22.
GND
22.
GND
20.
+24V
手按开关
PB01
9. OPEN-B
10. COM
AK02
BELL
BELL
+12V
GND
NC
PUSH/NO
OPENSW
DOOR1
DGND
3. +12V
4. GND
10. OPEN-B
AK04
+12V
GND
ALM
MSG
EXIT
D1
D0
NC
COM
NO
3. +12V
4. GND
2. GND
10. OPEN-B
Special Instructions
1 remote control is built, just reprovision 4 key remote control, can achieve "normally open" "restore" "jog", "full lock" feature.
You can also configure PB04 (wireless), realized the door function.
2 To achieve the outer lock function, just outside the accessory signal wire connected OPEN-B, door fittings signal line
connected to the OPEN-A, then press the lock button on the whole, to achieve the outer lock function. (Full lock signal only
lock OPEN-B, do not lock OPEN-A)
3 when making double open, according to the instructions received double doors sync signal lines. On power-up, all
parameters of the controller to ensure that the same two doors, door debugging, if there is the phenomenon of speed, shutter
speed can be adjusted switch, door switch amble speed, open pause time.
DIP switch master and slave select to use:
1 two doors simultaneously switch, the master from the selection DIP switch are appropriated above (re-power on after power
failure valid)
2 switch must have two doors will be closed after opening the door of the main appropriated from the following DIP switch
(power back on after a power outage valid)
www.smartpower.co.in