background image

Content

 

 

 
 
 
 

1  T e c h n i c a l   P a r a m e t e r s    

 

2  Components    

 

3  Installation  step    

 

 

3.1 Installation  of  bottom plate (SW 200A)    

 

 

3.2 Installation  of  bottom plate  (SW 200B)    

 

3.3 Installation  of  pull bar (Right)    

 

 

3.4 Installation  of  pull bar (Left)    

 

 

3.5  Installation  of  push bar (Right)    

 

 

3 .6  Installation  of  push bar (Left)    

 

 

3.7  Finished installation    

 

 

3.8  Installation  of  drive and  cover    

 

 

4  W ired  digram     

 

 

4.1  Terminal details of controller    

 

 

4.2  Date setting    

 

4.3  Connection  of commonly  used and special function

 

 

5  Trouble shooting    

 

1

 

 

2

 

 

3-10

 

 

3

 

 

4

 

 

5

 

 

6

 

 

7

 

 

8

 

 

9

 

 

10

 

 

11-13

 

 

11

 

 

12

 

 

13

 

 

14

 

Summary of Contents for SW200A

Page 1: ...MANUAL SW200A SW200B P U S H www smartpower co in ...

Page 2: ...f pull bar Right 3 4 Installation of pull bar Left 3 5 Installation of push bar Right 3 6 Installation of push bar Left 3 7 Finished installation 3 8 Installation of drive and cover 4 Wired digram 4 1 Terminal details of controller 4 2 Date setting 4 3 Connection of commonly used and special function 5 Trouble shooting 1 2 3 10 3 4 5 6 7 8 9 10 11 13 11 12 13 14 ...

Page 3: ...e 1 60s Temperature 20 55 Protection class IP12D Weight 6 5Kg Dimension SW200A 515 95 80mm L H W SW200B mm Door width kg Door weight Suitable range Limit range mm 1600 1200 1000 680 mm 1500 1200 1000 710 80 100 140 kg 180 80 100 140 kg 180 SW200A SW200B www smartpower co in ...

Page 4: ...1 Components SW200A 底板 拉臂 盖板 拉臂固定座 机组 SW200B 底板 拉臂 盖板 拉臂固定座 机组 配后备电源 2 www smartpower co in ...

Page 5: ...0 150 25 165 165 As the picture showing fix the bottom plate on the frame with eight countersunk head screw frame bottom plate Operator at door right power liner sensor liner 25 150 150 150 25 165 165 As the picture showing fix the bottom plate on the frame with eight countersunk head screw Operator at door left www smartpower co in ...

Page 6: ...0 200 35 210 210 As the picture showing fix the bottom plate on the frame with eight countersunk head screw frame bottom plate Operator at door right sensor liner power liner 35 200 150 200 35 210 210 As the picture showing fix the bottom plate on the frame with eight countersunk head screw Operator at door left www smartpower co in ...

Page 7: ... 30 3 3 Installation of pull bar A Right installation 230 230 20 170 Fix the pull bar on door leaf with 3 pics self tapping screw Door leaf Adjust the opening angle by position stopper position stopper www smartpower co in ...

Page 8: ...3 30 3 4 Installation of pull bar B Left installation 170 20 230 230 Fix the pull bar on door leaf with 3 pics self tapping screw Door leaf Adjust the opening angle by position stopper position stopper www smartpower co in ...

Page 9: ...on step 3 35 3 5 Installation of push bar A Right installation 如果有门边框 不适合安装 50 290 推臂固定座按图示尺寸用2个自攻螺丝 M6 15 紧固在门翼上 L Adjust the push bar lenght by two screw according to the door frame s depth L www smartpower co in ...

Page 10: ...on step 3 35 3 6 Installation of push bar B Left installation 如果有门边框 不适合安装 290 50 推臂固定座按图示尺寸用2个自攻螺丝 M6 15 紧固在门翼上 L Adjust the push bar lenght by two screw according to the door frame s depth L www smartpower co in ...

Page 11: ...lation step 3 7 Finished installation Pull bar Door leaf open toward inside same direction as operator operator Push bar Door leaf open toward outside opposite direction as operator operator www smartpower co in ...

Page 12: ...10 3 Installation step 3 8 驱动系统安装 将驱动系统按图示钩挂在已安装好的底板上 用8个内六角圆柱头螺丝紧固 3 9 机罩的安装与拆卸 www smartpower co in ...

Page 13: ...D 后备电源 24V GND 12V GND OPEN A COM 全锁 COM OPEN B COM 24V 12V GND closed crash door crash 4 2 Parameter adjustment instructions 代码 参数范围 出厂值 Features 01 30 99 53 Fast line speed door 02 30 99 43 Closing fast line speed 03 5 29 9 Open amble speed 04 5 29 8 Postponed closing speed 05 1 5 1 That pushed the door open efforts 06 0 5 0 When the door is closed closed force 07 0 1 0 Door mode selection 0 Pus...

Page 14: ... Power locks 18 GND 双门互锁 16 互锁信号 IN 14 互锁信号 OUT 13 同步信号 IN 11 同步信号 OUT 24G感应探头 16 互锁信号 IN 14 互锁信号 OUT 13 同步信号 IN 11 同步信号 OUT red black green yellow 1 24V 2 GND 9 OPEN B 10 COM 后备电源 18 GND 19 后备电源 V V N B 220V L B www smartpower co in ...

Page 15: ...ected to the OPEN A then press the lock button on the whole to achieve the outer lock function Full lock signal only lock OPEN B do not lock OPEN A 3 when making double open according to the instructions received double doors sync signal lines On power up all parameters of the controller to ensure that the same two doors door debugging if there is the phenomenon of speed shutter speed can be adjus...

Page 16: ...ed Loose stopper Adjust the stopper to the appropriate position and tighten The door is not operating 电源未接通 Check wiring blocks motor unit s power switch 接通电源 Learning speed setting is too low The value of a slow learning speed transfer large 门被锁 Are you sure the door is locked 打开门锁 拉臂固定座内有垃圾 Open the pull arm mounts at both ends of the side cover to check whether there is garbage 清除垃圾 Resistance ...

Page 17: ...15 ...

Reviews: