![SmartPower HR-10 Owner'S Manual Download Page 28](http://html.mh-extra.com/html/smartpower/hr-10/hr-10_owners-manual_1298083028.webp)
Smart Power Systems
®
A. C. MODULAR GENERATOR SYSTEM
Page 27 of 56
Figure 12
– Generator Output Wiring for 120VAC
WARNING:
Wiring of the A.C. modular generator system and electrical distribution throughout
the vehicle must be done in accordance with applicable sections in the National Fire
Protection Association’s document NFPA 1901, the National Electrical Code
®
and/or
other applicable, recognized electrical code and by a certified electrician.
Smart Power Systems
®
A.C. modular generators are supplied with the neutral bonded
to ground. Refer to National Fire Protection Association’s document NFPA 1901,
National Electrical Code
, and/or other applicable recognized electrical codes before
wiring an SPS A.C. modular generator system.
Never wire any loads to the generator’s output without a circuit breaker in series with
the load. Damage to the generator, to the components within that circuit, electrical
shock, or fire may result if a short occurs in an unprotected circuit. Run all 120/115
VAC and 240/230 VAC electrical connections between the generator and the
distribution panel in conduit. Bypassing the SPS factory installed breaker will void
the sy
stem’s warranty. Replacement breakers must be obtained from Smart Power
Systems
®
approved sources only.
Do not perform any wiring installations or modifications while the system is
operating. The A.C. modular generator system will generate enough voltage to
produce a fatal shock.
Never touch any live connections while the system is operating.
9.
Connect 12 VDC (vehicle battery positive) to the generator’s system controller input
(reference Figure 11). Connect the RED wire from the system controller, marked
“V12V supply” to the vehicle’s ignition circuit through a 30 amp fuse. Connect
the BLACK wire to the vehicle’s ground (vehicle battery negative).
WARNING:
12 volts DC must be directly applied to the generator system controller whenever the
hydraulic pump is engaged. Failure to do so may cause excessive fluid temperature,
damaging the system components and will void the warranty.
Never come near a running fan with loose items such as long hair, clothing, jewelry,
ties, items that can fall out of pockets, etc.
Never operate the system with fan disabled or removed. System over-heating will
result and this will void the system’s warranty.
Improper wiring of the generator system to the vehicle may discharge the vehicle
battery, cause a fire, or cause improper operation of the generator system.