Step-by-Step Instructions
1.
Disconnect the power at the circuit breaker or fuse panel. Verify that the power has
been removed by testing the wires for voltage.
2.
Remove the trim plate from the existing switches.
3.
Unscrew and pull the existing switches from the wall box.
4.
Disconnect the wires from the existing switches.
5.
If the SwitchLinc Transmitter is being installed into a
3/4/5-way circuit, the SwitchLinc Multi-way Companion
Switch must be installed in the wall box where power
comes into the circuit. Follow the instructions included
with the Multi-way Companion Switch to identify the "Hot,"
"Neutral," "Ground," and "Traveler" wires.
6.
Orient SwitchLinc Transmitter so the LED is at the top and make connections
according to the “SwitchLinc Transmitter Wiring Diagram”. Wire Multi-way
Companion Switches (if used) according to the “SwitchLinc Transmitter Multi-Way
Wiring Diagram”.
7.
After all connections have been made, ensure that all wire connectors are firmly
attached and that there is no exposed copper except for the Ground wire.
8.
Gently place the wires and switch into the wall box (with LED at top) and screw into
place.
9.
Turn the circuit breaker back on.
10. The Status LED/ Set Button will illuminate with a steady green glow.
12. After testing SwitchLinc Transmitter for proper operation, install the faceplate (sold
separately).
Tip:
For additional
help installing 3-way
circuits, see page 5 in
the Multi-way
Companion Switch
manual.
4