CAUTION!!
Read and understand these instructions before installing.
This device is intended for installa-
tion in accordance with the National Electric Code and local regulations in the United States, or
the Canadian Electrical Code and local regulations in Canada. To reduce the risk of overheating
and possible damage to other equipment, do not install a SwitchLinc to control a receptacle or
fluorescent lighting fixture. For indoor use only. Connect only copper or copper-clad wire to this
device. Before installing, disconnect power at circuit breaker or remove fuse to avoid shock or
damage to the control. It is recommended that a qualified electrician perform this installation.
Retain these instructions for future reference.
Quick Start Instructions
DEFAULT
Setting the Transmitter’s
1. Press and hold the Set Button for 3
A-1
Primary Address
seconds (the LED will begin blinking)
2. Send the desired address from any
transmitter within 30 seconds
(see page 5 for more detailed instructions)
Factory Reset
1. Gently pull the Set Button out
to remove power for 5 seconds
2. Push and hold in the Set Button
Resets to
for 5 seconds, then release
default
3. When the LED Indicator comes on,
settings
the SwitchLinc Transmitter is reset
(see page 6 for more detailed instructions)
Preparation
Before installing the SwitchLinc Transmitter, please take the necessary precautions
listed here:
• Be sure that the fuse has been removed or the circuit breaker is turned off to the
circuit being controlled. Installing the SwitchLinc Transmitter with the power on
will expose you to dangerous voltages.
• The Wiring Diagram on page 5 will help you to determine the wire colors of the
connections to the SwitchLinc Transmitter and Multi-Way Companion Switch.
Note: While the neutral connection is optional on the Multi-Way Companion
Switch, the SwitchLinc Transmitter requires a neutral connection.
• Wiring for 3-way, 4-way, & up switch circuits follow conventional (standard, non-
remote) wiring practice (plus the requirement for a neutral). Wiring the
SwitchLinc Multi-Way Companion Switch requires the Line (Black) wire be acces-
sible and be the same 110V leg of the house wiring. The White wire on the
Multi-Way Companion Switch is connected to NEUTRAL ONLY. If neutral is not
available, cap the White wire, which will simply causes the nightlight LED not to
function.
• Installation should be performed only by a qualified electrician, or by a homeown-
er who is familiar and comfortable with electrical circuitry. If there are any ques-
tions, consult an electrician or contact Smarthome's Tech Support department
for guidance.
3
12080_web.qxd 6/25/2004 1:31 PM Page 3