Operating & installation instructions bravour
Subject to technical changes.
V 2.1.5
www.SmartHeat.de
>>
13
6
Transportation
Before delivery our products are checked if they are without damages and functional and finally they are packed.
In order that the cooling circuit and the function of compressors are not impaired it is necessary to transport the heat
pump vertically.
Imperatively avoid serious impacts. The sensitive spring-supported bearing of the compressors might get damaged.
Observe the weight of the heat pump and use appropriately dimensioned transportation means. It is recommended to
use a lift truck or a similar device in order to transport the unit to the installation place.
7
Installation
General notes
Install the heat pump in a way that the field service can easily perform commissioning and maintenance works and en-
sure free working space on all sides (refer to the recommended minimum clearances).
The installation space must be dry and frost-free and have a plane and horizontal ground. The ground must be dimen-
sioned according to the weight of the SmartHeat bravour heat pump. The connection to the heating and heat source
system should be as short as possible.
When installing the heat pump among others the requirements of the correspond-
ing accident prevention regulations BGV D4 for the use of refrigerants of the
group A1 must be complied with!
Environmental temperature max. 40°C
Environmental temperature min. 5°C
Environmental humidity max. 80 % (not condensed)
Ensure a dry, frost-free installation space and make sure that the floor structure
escapable of bearing the unit!
The transportation of the heat pump must be performed with care. It is only al-
lowed to tilt the machine cabinet to more than 45° for a short term in order to
insert it.