background image

 

 
 
 
 
 

SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. 

HRC200 

INDUSTRIAL REMOTE CONTROL 

USER MANUAL 

Summary of Contents for HRC200

Page 1: ...SMARTGEN ZHENGZHOU TECHNOLOGY CO LTD HRC200 INDUSTRIAL REMOTE CONTROL USER MANUAL...

Page 2: ...produced in any material form including photocopying or storing in any medium by electronic means or other without the written permission of the copyright holder Applications for the copyright holder...

Page 3: ...2 HRC200M RECEIVER PANEL INDICATORS AND INTERNAL KEYS 8 4 3 COMMUNICATION CHANNEL CONFIGURATION 8 4 4 PAIRING 9 4 5 RS485 INTERFACE 10 4 6 RECEIVER WIRING TERMINAL 11 5 PROGRAMMABLE PARAMETERS 12 5 1...

Page 4: ...omposed of remote control HRC200R and receiver HRC200M applying LoRa wireless transmission chip Remote Control Can realize remote start stop load unload emergency stop and other functions indicate eng...

Page 5: ...istics Storage Condition Temperature 30 80 C Weight 0 2kg without battery Receiver HRC200M Working Voltage DC 8 35 V Overall Consumption 1 2W Aux Input Port B connected is active Aux Output Port Relay...

Page 6: ...when battery voltage is normal Connection Status Indicator flashes yellow during pairing process Press the key indicator flashes red once when sending indicator flashes green once when receiving succe...

Page 7: ...ong press this key 6s to enter pairing press it again during the pairing process to cancel pair Press this key to send F2 command see the following description Load Press this key to send load command...

Page 8: ...cation fails LoRa Indicator green Flashing communication with remote control is normal Always extinguishing communication with remote control fails PAIR key Long press it 6s to enter pairing mode Pres...

Page 9: ...470 7 0111 475 8 1000 480 9 1001 475 10 1010 485 11 1011 490 12 1100 495 13 1101 500 14 1110 505 15 1111 515 It is 1 when the dial switch is set to ON position otherwise it is 0 NOTE When the dial swi...

Page 10: ...than 3 5mm in diameter into the PAIR hole vertically then long press PAIR key 6s LoRa RS485 and POWER indicator flash green Press PAIR key again during LoRa pairing can cancel pair 3 Turn on the remot...

Page 11: ...m2 Normally open volt free output capacity DC30V 2A 5 AUX OUTPUT2 0 75mm2 Normally open volt free output capacity DC30V 2A 6 AUX OUTPUT1 0 75mm2 Normally open volt free output capacity DC30V 2A 7 TR R...

Page 12: ...RS485 communication conversion module then the related parameter configuration of receiver can be done via PC software After the configuration is completed dial switch must recover to previous positio...

Page 13: ...Output 3 0 6 0 10 Aux Output 4 0 6 0 11 Aux Output 5 0 6 0 12 Aux Output 1 Output Delay 0 999 9 s 1 0s When it is set as 0 relay continuously outputs when the remote control key is firstly pressed re...

Page 14: ...ning Status 2 Aux Input 2 9 Alarm Status 3 Aux Output 1 2 Stop Control 4 Aux Output 2 4 Load Control 5 Aux Output 3 3 Unload Control 6 Aux Output 4 1 Start Control ACC7100A 1 Aux Output 2 38 Start Suc...

Page 15: ...LATION DIMENSIONS 7 1 REMOTE CONTROL OVERALL DIMENSION Unit mm Fig 9 HRC200R Overall Dimension 7 2 RECEIVER OVERALL DIMENSION Installation method can be 35mm guide rail installation or screw M4 instal...

Page 16: ...er communication address baud rate parity bit stop bit set is correct Check whether A and B of RS485 are reversely connected Try to connect 120 terminal matching resistor Pairing Failure Check whether...

Reviews: