HA Profile (0x0104)                                                                                    Device ID: 

0x0007

                                                                                                                     

Combined Interface Device

End 

Point

Cluster 

ID

Cluster Name

Client/

Server

Cluster Description

01

0x0204

Thermostat UI Config

Client

An interface for configuring the user interface of a thermostat (which may be 

remote from the thermostat)

01

0x0400

Illuminance Measurement

Client

Attributes and commands for configuring the measurement of illuminance, 

and reporting illuminance measurements

01

0x0401

Illuminance Level Sensing

Client

Attributes and commands for configuring the sensing of illuminance levels, 

and reporting whether illuminance is above, below, or on target.

01

0x0402

Temperature Measurement

Client

Attributes and commands for sensing illuminance level

01

0x0403

Pressure Measurement

Client

Attributes and commands for configuring the measurement of pressure, and 

reporting pressure measurements.

01

0x0404

Flow Measurement

Client

Attributes and commands for configuring the measurement of flow, and 

reporting flow rates.

01

0x0405

Rel. Hum. Measurement

Client

Attributes and commands for configuring the measurement of relative humid

-

ity, and reporting relative humidity measurements.

01

0x0406

Occupancy Sensing

Client

Attributes and commands for configuring occupancy sensing, and reporting 

occupancy status.

01

0x0500

IAS Zone

Client

Attributes and commands for IAS security zone devices.

01

0x0501

IAS ACE

Client

Attributes and commands for IAS Ancillary Control Equipment.

01

0x0502

IAS WD

Client

Attributes and commands for IAS Warning Devices.

01

0x0702

Simple Metering

Client

Provides mechanism to retrieve electric power usage

ZigBee Clusters

Summary of Contents for 2011D

Page 1: ...ands via serial communication This interface is intended for use with applications that can handle serial communication Docklight Scripting is one application that can be used to set up a ZigBee network and control individual ZigBee devices with the IOT ZBCID An understanding of the ZBCID API will be required to modify Docklight scripts For a brief tutorial on how to use Docklight with the pre loa...

Page 2: ...l parameters among devices 01 0x000C Analog Input Basic Client An interface for reading the value of an analog measurement and accessing various characteristics of that measurement 01 0x000D Analog Output Basic Client An interface for setting the value of an analog output typically to the environment and accessing various characteristics of that value 01 0x000E Analog Value Basic Client An interfa...

Page 3: ...low or on target 01 0x0402 Temperature Measurement Client Attributes and commands for sensing illuminance level 01 0x0403 Pressure Measurement Client Attributes and commands for configuring the measurement of pressure and reporting pressure measurements 01 0x0404 Flow Measurement Client Attributes and commands for configuring the measurement of flow and reporting flow rates 01 0x0405 Rel Hum Measu...

Page 4: ...he user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Notice This device complies w...

Page 5: ... appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement This EUT is compliance with SAR for general population uncontrolled exposure limits in IC RSS 102 and had been tested in accordance with the measurement methods and procedures specified in IEEE 152...

Reviews: