background image

Longo programmable controller LPC-2.NE1 module

STANDARDS   AND   PROVISIONS:   Standards,   recommendations, 
regulations and provisions of the country in which the devices 

will operate, must be considered while planning and setting up 
electrical   devices.   Work   on   230   VAC   network   is   allowed   for 

authorized personnel only.
DANGER   WARNINGS:   Devices   or   modules   must   be   protected 

from moisture, dirt and damage during transport, storing and 
operation.

WARRANTY CONDITIONS: For all modules LONGO LPC-2 – if no 
modifications are performed upon and are correctly connected 

by   authorized   personnel   –   in   consideration   of   maximum 
allowed  connecting  power,  we  offer  warranty  for   24   months 

from   date   of   sale   to   end   buyer.   In   case   of   claims   within 
warranty time, which are based on material malfunctions the 

producer   offers   free   replacement.   The   method   of   return   of 
malfunctioned   module,   together   with   description,   can   be 

arranged   with   our   authorized   representative.   Warranty   does 
not   include   damage   due   to   transport   or   because   of 

unconsidered corresponding regulations of the country, where 
the module is installed.

This   device   must   be   connected   properly   by   the   provided 
connection scheme in this manual. Misconnections may result 

in device damage, fire or personal injury.
Hazardous voltage in the device can cause electric shock and 

may result in personal injury or death.
NEVER SERVICE THIS PRODUCT YOURSELF!

This device must not be installed in the systems critical for life 
(e.g. medical devices, aircrafts, etc.). 

If   the   device   is   used   in   a   manner   not   specified   by   the 
manufacturer,   the   degree   of   protection   provided   by   the 

equipment may be impaired.

Waste   electrical   and   electronic   equipment   (WEEE)   must   be 
collected separately! 

LONGO LPC-2 complies to the following standards:

EMC: IEC 61131-2

LVD: IEC 61131-2

Vibrations and climatic-mechanical: EN 60068-2-6, EN 60068-

2-27, EN 60068-2-29

Smarteh d.o.o. operates a policy of continuous development. 

Therefore   we   reserve   the   right   to   make   changes   and 
improvements to any of the products described in this manual 

without any prior notice.

MANUFACTURER:
SMARTEH d.o.o.

Trg tigrovcev 1
5220 Tolmin

Slovenia

ii

Summary of Contents for LPC-2.NE1

Page 1: ...USER MANUAL Longo programmable controller LPC 2 NE1 module Version 4 SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si...

Page 2: ...Longo programmable controller LPC 2 NE1 module Written by Smarteh d o o Copyright 2012 SMARTEH d o o User Manual Document Version 004 July 1 2012 i...

Page 3: ...de damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in...

Page 4: ...ler LPC 2 NE1 module 1 DESCRIPTION 1 2 FEATURES 2 3 INSTALLATION 3 3 1 Connection scheme example 3 3 2 Mounting instructions 5 3 3 Module labeling 6 4 OPERATION 7 4 1 IP and MAC setting 7 4 2 Modbus p...

Page 5: ...intended to connect LPC 2 standalone system with LAN It acts as Modbus slave device using TCP IP protocol IP and MAC addresses are configurable from main controller module application NOTE For proper...

Page 6: ...2 NE1 communication module Table 1 Technical data Compliant to Ethernet II and IEEE802 3 10Base5 10Base2 10BaseT 10Mbps IP and MAC address management Modbus slave device mode TCP IP protocol Modbus co...

Page 7: ...Longo programmable controller LPC 2 NE1 module 3 INSTALLATION 3 1 Connection scheme example Figure 2 Connection scheme example 3...

Page 8: ...e Table 3 marking and indication LED1 RUN status OFF no power supply ON power supply present UART communication to LPC 2 MC7 not active BLINK ON every 4s for 1s power supply present UART communication...

Page 9: ...t each module to the DIN rail first then attach modules together through K1 and K2 connectors 4 Connect devices and sensor wires according to the connection scheme in Figure 2 5 Switch ON main power s...

Page 10: ...8 year of production Label 2 description 1 S N NE1 S9 0800000003 is the serial number NE1 short product name S9 user code test procedure e g Smarteh person xxx 08 year last two cyphers 00000003 curren...

Page 11: ...n second hex noted pair of OUI 48 bit MAC notation last hex noted pair of OUI 48 bit MAC notation 4 2 Modbus protocol usage LPC 2 NE1 Ethernet adapter is Modbus slave device and supports Modbus comman...

Page 12: ...Modbus functions NE1_x_bOUT001 NE1_x_bOUT002 NE1_x_bOUT128 Discrete input bit size 1 2 128 0x02 NE1_x_bIN001 NE1_x_bIN002 NE1_x_bIN128 Coil bit size 1 2 128 0x05 0x0F 0x01 NE1_x_wOUT001 NE1_x_wOUT002...

Page 13: ...ection type RJ45 FM connector suitable mating RJ45 male cable connector Dimensions L x W x H 90 x 18 x 60 mm Supported protocol Modbus TCP slave Weight 50 g Ambient temperature 0 to 50 C Ambient humid...

Page 14: ...following table describes all the changes to the document Date V Description 1 7 2012 004 CGP General update 11 5 2010 003 Updated warranty permanence 23 3 2010 002 added Label 3 description 23 4 200...

Page 15: ...Longo programmable controller LPC 2 NE1 module 7 NOTES 11...