Longo programmable controller LPC-2.IR2V

STANDARDS   AND   PROVISIONS:   Standards,   recommendations,
regulations and  provisions of  the country in which the devices will
operate, must be considered while planning and setting up electrical
devices. Work on  100 .. 240 V AC  network is allowed for authorized
personnel only.

DANGER   WARNINGS:   Devices   or   modules   must   be   protected   from
moisture, dirt and damage during transport, storing and operation.

WARRANTY   CONDITIONS:   For   all   modules   LONGO   LPC-2   –   if   no
modifications   are   performed   upon   and   are   correctly   connected   by
authorized   personnel   –   in   consideration   of   maximum   allowed
connecting power, warranty of 24 months is valid from the date of
sale to the end buyer, but not more than 36 months after delivery
from Smarteh. In case of claims within warranty time, which are based
on material malfunctions the producer offers free replacement. The
method of return of malfunctioned module, together with description,
can be arranged with our authorized representative. Warranty does
not   include   damage   due   to   transport   or   because   of   unconsidered
corresponding   regulations   of   the   country,   where   the   module   is
installed.
This device must be connected properly by the provided connection
scheme in this manual. Misconnections may result in device damage,
fire or personal injury.
Hazardous  voltage   in  the  device  can  cause  electric  shock  and  may
result in personal injury or death.
NEVER SERVICE THIS PRODUCT YOURSELF!
This device must not be installed in the systems critical for life (e.g.
medical devices, aircrafts, etc.).

If the device is used in a manner not specified by the manufacturer,
the degree of protection provided by the equipment may be impaired.

Waste electrical and electronic equipment (WEEE) must be collected
separately!

LONGO LPC-2 complies to the following standards:

EMC:  EN 61000-6-3:2007 + A1:2011, EN 61000-6-1:2007, EN 61000-3-

2:2006 + A1:2009 + A2: 2009, EN 61000-3-3:2013

LVD: IEC 61010-1:2010 (3

rd

 Ed.), IEC 61010-2-201:2013 (1

st

 Ed.)

Smarteh   d.o.o.   operates   a   policy   of   continuous   development.
Therefore we reserve the right to make changes and improvements to
any of the products described in this manual without any prior notice.

MANUFACTURER:
SMARTEH d.o.o.
Poljubinj 114
5220 Tolmin
Slovenia

ii

Summary of Contents for LPC-2.IR2V

Page 1: ...USER MANUAL Longo programmable controller LPC 2 IR2V Multisensor Version 5 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 388 44 00 e mail info smarteh si www smarteh si...

Page 2: ...Longo programmable controller LPC 2 IR2V Written by SMARTEH d o o Copyright 2019 SMARTEH d o o User Manual Document Version 5 April 2019 i...

Page 3: ...ot include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection s...

Page 4: ...ION 2 3 FEATURES 3 4 OPERATION 4 4 1 Operational modes 4 4 2 Parameters 4 4 3 IR learn receive and transmit 7 5 INSTALLATION 8 5 1 Connection scheme 8 5 2 Mounting frame selection 10 5 3 Mounting inst...

Page 5: ...Longo programmable controller LPC 2 IR2V 1 ABBREVIATIONS Sorted by order of appearance in document IR Infrared LED Light emitting diode PWR Power ERR Error DIP Dual in line package SEL Selector 1...

Page 6: ...the information needed for achieving good work conditions IR transmit feature can be used for remote controller substitution for example air conditioning can be controlled from Smarteh main module via...

Page 7: ...for light intensity measurement IR receive transmit Programmable IR transceiver RC 5 IR protocol receiver Daikin Toshiba Hitachi Panasonic Mitsubishi IR protocol transmitter 2 diagnose LED Modular fr...

Page 8: ...le to the LPC 2 IR2V Command IR command number selection for transmit oIrCmdSendNum This parameter is used to select the IR learned command which will be used for transmit Type WORD Raw to engineering...

Page 9: ...ring data 0 2990 0 2990 lux Act Room temp iTAct Actual room temperature measured by wireless panel Type WORD Raw to engineering data 0 5000 0 00 C 50 00 C Act Room RH iRhAct Room humidity measured by...

Page 10: ...hich includes toggle bit address code and data code of the RC 5 protocol When button is released value gets to 0 after next communication cycle with main module or after approximately two seconds rega...

Page 11: ...h protocol should be used for IR receive user can select with IrProtocolSel parameter To check if the IR command has been learned and stored correctly IrProtocolSel parameter must be 0 Set the DIP swi...

Page 12: ...Longo programmable controller LPC 2 IR2V 5 INSTALLATION 5 1 Connection scheme Figure 2 Connection scheme 8...

Page 13: ...lt OFF RS 485 communication OK LED2 green Power supply ON power supply OK OFF power supply missing or power off LED3 orange Signalization Programmable Table 4 S1 SEL for IR Switch 1 Switch 2 Switch 3...

Page 14: ...ible with LPC 2 IR2V module Bticino Living Light Gewiss Playbus System Vimar Plana Idea Tem Master Frames of other vendors most probably suits as well but they were not verified by Smarteh Before inst...

Page 15: ...e and 1 cm off the wall Recommended installation height is 1 5 m above floor level Mounting instructions 1 Set the correct RS 485 address S2 switch for LPC 2 IR2V table 5 2 Connect interconnection cab...

Page 16: ...ion code 002 version code reserved for future HW and or SW firmware upgrades 3 D C 01 19 is the date code 01 week and 19 year of production Label 2 descriptions 1 S N IR2V S9 1900000003 is the serial...

Page 17: ...min pulse length in protocol used for learning 250 us IR max number of pulses for learning single IR command 550 Dimensions W x H x D 24 x 48 x 52 mm Weight 20 g Maximum altitude 2000 m Mounting posit...

Page 18: ...are parts following Part Numbers should be used LPC 2 IR2V Infrared transceiver and light sensor LPC 2 IR2V P N 225IR218V01002 LPC 2 RC1S remote control LPC 2 RC1S P N 225RC116001001 Interconnection c...

Page 19: ...following table describes all the changes to the document Date V Description 12 04 19 5 Technical update 29 03 19 4 Technical update 18 01 17 3 Technical update 16 11 16 2 Added IR data 30 10 16 1 Th...

Page 20: ...Longo programmable controller LPC 2 IR2V 9 NOTES 16...

Reviews: