background image

Longo programmable controller LPC-2.CR1

STANDARDS   AND   PROVISIONS:   Standards,   recommendations,
regulations and  provisions of  the country in which the devices will
operate, must be considered while planning and setting up electrical
devices.   Work   on   230   V   AC   network   is   allowed   for   authorized
personnel only.

DANGER   WARNINGS:   Devices   or   modules   must   be   protected   from
moisture, dirt and damage during transport, storing and operation.
WARRANTY   CONDITIONS:   For   all   modules   LONGO   LPC-2   –   if   no
modifications   are   performed   upon   and   are   correctly   connected   by
authorized   personnel   –   in   consideration   of   maximum   allowed
connecting power, we offer warranty for 24 months from date of sale
to end buyer. In case of claims within warranty time, which are based
on material malfunctions the producer offers free replacement. The
method of return of malfunctioned module, together with description,
can be arranged with our authorized representative. Warranty does
not   include   damage   due   to   transport   or   because   of   unconsidered
corresponding   regulations   of   the   country,   where   the   module   is
installed.
This device must be connected properly by the provided connection
scheme in this manual. Misconnections may result in device damage,
fire or personal injury.
Hazardous  voltage   in  the  device  can  cause  electric  shock  and  may
result in personal injury or death.
NEVER SERVICE THIS PRODUCT YOURSELF!
This device must not be installed in the systems critical for life (e.g.
medical devices, aircrafts, etc.). 
If the device is used in a manner not specified by the manufacturer,
the degree of protection provided by the equipment may be impaired.

Waste electrical and electronic equipment (WEEE) must be collected
separately! 

LONGO LPC-2 complies to the following standards:

EMC:EN 61000-6-2 (EN 50082), EN 61000-6-4 (EN 50081)

LVD: IEC 61131-2

Vibrations and climatic-mechanical: EN 60068-2-6, EN 60068-2-27,
EN 60068-2-29

Smarteh   d.o.o.   operates   a   policy   of   continuous   development.
Therefore we reserve the right to make changes and improvements to
any of the products described in this manual without any prior notice.

MANUFACTURER:
SMARTEH d.o.o.
Poljubinj 114
5220 Tolmin
Slovenia

ii

Summary of Contents for LPC-2.CR1

Page 1: ...USER MANUAL Longo programmable controller LPC 2 CR1 Card Reader module Version 5 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si...

Page 2: ...Longo programmable controller LPC 2 CR1 Written by SMARTEH d o o Copyright 2016 SMARTEH d o o User Manual Document Version 005 June 2016 i...

Page 3: ...ransport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misco...

Page 4: ...ntroller LPC 2 CR1 1 ABBREVIATIONS 1 2 DESCRIPTION 2 3 FEATURES 3 4 OPERATION 4 4 1 Parameters 4 5 INSTALLATION 5 5 1 Connection scheme 5 5 2 Mounting instructions 7 5 3 Module labeling 8 6 TECHNICAL...

Page 5: ...ontroller LPC 2 CR1 1 ABBREVIATIONS Sorted by order of appeareance in document RFID Radio frequency identification SOS Emergency call LED Light emitting diode DIP Dual in line package ID Identity MCU...

Page 6: ...ck opening turning light on If key card number is not valid the red LED blinks and a longer beep is generated Functionalities are controlled from MCU Controller is accompanied with Smarteh IDE applica...

Page 7: ...rammable controller LPC 2 CR1 3 FEATURES Figure 1 LPC 2 CR1 module Table 1 Technical data RFID reader OK LED Fault X LED Power LED Internal fault LED Internal built in buzzer Black or white glass poss...

Page 8: ...eter has logical value 0 is considered to be inactive disabled or cleared Parameter can be feedback or command Parameter as feedback means that CR1 module is sending information to MCU On the other ha...

Page 9: ...Longo programmable controller LPC 2 CR1 5 INSTALLATION 5 1 Connection scheme Figure 2 Connection scheme 5...

Page 10: ...ault X ON RFID key standard NOK or ID card number wrong OFF No tag in proximity LED2 green OK ON RFID key standard OK and ID card number valid OFF No tag in proximity LED5 red Communication ON RS 485...

Page 11: ...ule Bticino Living Light Gewiss Playbus System Vimar Plana Idea Tem Modul Soft Modul Line Master Frames of other vendors most probably suits as well but they were not verified by Smarteh Before instal...

Page 12: ...n panels Mounting of RFID panels into conductive metal frames is not allowed RFID panel should not be positioned close to conductive areas 1 Set the correct RS 485 address S1 switch for LPC 2 CR1 refe...

Page 13: ...ounting module 01 derivation code 001 version code reserved for future HW and or SW firmware upgrades 3 D C 01 10 is the date code 01 week and 10 year of production Label 2 descriptions 1 S N CR1 S9 1...

Page 14: ...Power consumption 1 5 W RFID type EM4100 125 kHz Manchester 64 read only HITAG2 UID read only Max reading distance 4 cm Dimensions W x H x D 75 x 49 x 29 mm Weight 40 g Ambient temperature 0 to 50 C A...

Page 15: ...umbers should be used LPC 2 CR1 Card Reader module LPC 2 CR1 EM black P N 225CR109V01001 LPC 2 CR1 Card Reader module LPC 2 CR1 EM white P N 225CR115V01W01 LPC 2 MC8 Main module LPC 2 MC8 P N 225MC813...

Page 16: ...describes all the changes to the document Date V Description 07 06 2016 5 General update 01 06 2014 4 Power consumption data update 01 02 2013 3 Technical update 01 07 2012 2 CGP General update 18 03...

Page 17: ...Longo programmable controller LPC 2 CR1 9 NOTES 13...