7.7. Output Parameters
Using the output parameters, current and voltage can be configured individually for each
channel. These parameters should only be applied carefully, meeting the specifications of the
connected LED illumination. Too high output parameters can lead to permanent damage of the
illumination.
Figure 33: ScLibClient
– Output Parameters
Parameters:
•
Load Channel n
– Available output channel(s) which can be configured independently
•
Current
– Current for the individual output line
•
Trigger
– Trigger which will be used to drive the output line(s)
•
Measured Current
/ Voltage
– Actual measured voltage and current at the output lines
•
Voltage Output 1
– Maximum voltage the internal switching power supply will be able to
provide. The actual (measured) voltage of each line will be depending of the illumination
characteristics and the configured current.