SMART 433-CMU Installation And Use Instructions Manual Download Page 6

WIRELESS CALL SYSTEM

CALL REVIEW

VOLUME

LANGUAGE

REPLACE/ADD

RECORD/ADD

RESET

1   2   3   4   5   6   7   8   9   10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30 

WIRELESS CALL SYSTEM

CALL REVIEW

VOLUME

LANGUAGE

REPLACE/ADD

RECORD/ADD

RESET

1   2   3   4   5   6   7   8   9   10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30 

WIRELESS CALL SYSTEM

CALL REVIEW

VOLUME

LANGUAGE

REPLACE/ADD

RECORD/ADD

RESET

1   2   3   4   5   6   7   8   9   10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30 

WIRELESS CALL SYSTEM

CALL REVIEW

VOLUME

LANGUAGE

REPLACE/ADD

RECORD/ADD

RESET

1   2   3   4   5   6   7   8   9   10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30 

WIRELESS CALL SYSTEM

CALL REVIEW

VOLUME

LANGUAGE

REPLACE/ADD

RECORD/ADD

RESET

1   2   3   4   5   6   7   8   9   10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30 

WIRELESS CALL SYSTEM

CALL REVIEW

VOLUME

LANGUAGE

REPLACE/ADD

RECORD/ADD

RESET

1   2   3   4   5   6   7   8   9   10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30 

WARNING:

 If you do not wait for the Central Monitor to make a melodic tone before pressing the next Nurse Call Button or other 

component, each component will be programmed to the same number on the Central Monitor. In this situation, the Central Monitor will 
speak one number for the component, but show a different number to represent the room. When multiple components are programmed to 
the same number on the Central Monitor, 

THE NUMBER SPOKEN WILL NOT CORRESPOND WITH THE NUMBER DISPLAYED

. This may be 

useful when multiple devices are being used in the same room, but not for any other situation.

433-CMU

433-CMU

433-CMU

433-CMU

433-CMU

433-CMU

a

b

a

e

c

c

CordLess® Transmitter (

TM-03

) (optional) Programming Instructions

Press on the sensor pad or step on floor 
mat. The Central Monitor will speak and 
display a number. The number shown is the 
Cordless Transmitter’s identification number 
on the Central Monitor.

Plug a CordLess® Transmitter into a CordLess® 

Sensor Pad or Floor Mat. Repeat this step for 

every CordLess Pad and Transmitter 

you plan to use with the Central 

Monitor system.

Press and hold “Record/
Add” button until you  
hear 2 dings and a 
melodic tone.

Press and hold “Record/
Add” button until you hear 
2 dings and a melodic 
tone.

Wait for the Central Monitor 
to make a melodic tone. Then, 
repeat steps “c” & “d” with the 
next Monitor Adaptor or follow 
programming directions for 
another component that you 
would like to program. 

Wait for the Central Monitor to 
make a melodic tone. Then, repeat 
step “c” with the next Exit Alarm 
or follow programming directions 
for another component that you 
would like to program. 

Turn on the transmitter. The 
ON/OFF switch located on the 
side of the Transmitter.

Sensor 

Pad

d

TM-03 
CordLess®
Transmitter

ON/OFF Switch

b

433-EXT Door/Window Exit Alarm (optional) Programming Instructions

Touch the two parts of the Exit 
Alarm together and then the Central 
Monitor will display and speak the 
number the Exit Alarm has been 
programmed to.

f

d

Press the “Reset” button to 
exit programming mode.

Press the “Reset” button to 
exit programming mode.

433-EXT

TM-03

TM-02

6

Summary of Contents for 433-CMU

Page 1: ...23 12V 433 PGD Caegiver Pocket Pager with LCD Display 433 PG Caegiver Pocket Pager 433 NC Wireless Nurse Call Button Optional Accessories WIRELESS CALL SYSTEM CALL REVIEW VOLUME LANGUAGE REPLACE ADD R...

Page 2: ...2 This page intentionally left blank...

Page 3: ...lay optional 433 NCNurseCallButton optional _ A23 12V _ A23 12V Front Top Inside Insert a flathead screwdriver into notch and gently twist until the button pops open Gently pry open using tab at top o...

Page 4: ...ase the next Nurse Call Button or other component that you would like to program repeating step b until all buttons components have been programmed Call Alarm Unlock Lock Pager VOL LANGUAGE REVIEW Pag...

Page 5: ...sired the Fall Alarm Monitor TL 2100 series Plug the sensor pad floor mat or seat belt into phone style port at bottom of desired Fall Alarm Monitor TL 2100 series Press sensor pad step on floor mat o...

Page 6: ...RESPOND WITH THE NUMBER DISPLAYED This may be useful when multiple devices are being used in the same room but not for any other situation 433 CMU 433 CMU 433 CMU 433 CMU 433 CMU 433 CMU a b a e c c C...

Page 7: ...Call Review and Reset features refer to pages 7 and 8 of these instructions ON OFF VOL LANGUAGE REVIEW Pager VOL LANGUAGE REVIEW up to 300 feet IMPORTANT The end user is responsible for testing syste...

Page 8: ...r component 1 Press and hold Replace Add Button until you hear 2 dings and a melodic tone 2 Repeatedly press the Call Review Button to scroll through the numbers on the Central Monitor until you get t...

Page 9: ...ramming mode WARNING Pressing the Record Add button will erase clear all programming from the Central Monitor After pressing the Record Add button all Nurse Call Buttons or other components that were...

Page 10: ...you remove batteries when the Central Monitor is not in use When batteries are replaced all Nurse Call Buttons and other components that were programmed to work with the Central Monitor prior to remo...

Page 11: ...This page intentionally left blank...

Page 12: ...implied warranties Except for this limited warranty NO EXPRESS OR IMPLIED WARRANTIES ARE GIVEN AND NO AFFIRMATION OF SELLER BY WORDS OR ACTION WILL CONSTITUTE A WARRANTY THE GOODS BEING PURCHASED ARE...

Reviews: