background image

FRU-20-01032-20 

Replacing the lamp on your 

SMART Table™ ST230i

These instructions guide you through the replacement of the projector lamp in your
SMART Table™ ST230i. The average life of a projector lamp is 2000 hours. When the 
projector lamp has been used for 2000 hours or more, the following message appears 
on your SMART Table’s surface:

It is time to replace the lamp. Use the procedure in the User’s Guide to replace 
the lamp as soon as possible.

After 2100 hours of use, the following message appears on your SMART Table’s 
surface for 10 seconds, and then the projector turns off:

The lamp has exceeded its service life! The projector will not turn on until you 
replace the lamp.

NOTE

In some situations, the projector lamp may start to dim before 2000 hours of use. 
Replace the projector lamp in these situations as well.

To replace the lamp, you must:

disconnect the cables and vent hose from the projector (page 3)

remove the projector and bracket from inside the cabinet (page 5)

replace the projector lamp module (page 7)

reattach the projector to the bracket (page 9)

attach the cables and vent hose to the projector (page 9)

reset the lamp timer (page 10)

This Kit Contains

Tools Required (but not included)

• Replacement Lamp Module

• Phillips® No. 2 screwdriver

• 5 mm hex key

Summary of Contents for SMART Table ST203i

Page 1: ...ce for 10 seconds and then the projector turns off The lamp has exceeded its service life The projector will not turn on until you replace the lamp NOTE In some situations the projector lamp may start...

Page 2: ...n ventilate the area where the lamp shattered or burst Wash your hands thoroughly if you have come into contact with lamp debris Thoroughly clean the area around the projector and discard any edible i...

Page 3: ...local regulations Disconnecting the Cables and Vent Hose Before you can remove the projector from the mounting bracket you must disconnect the cables and vent hose from the projector To disconnect the...

Page 4: ...4 FRU 20 01032 20 REPLACING THE LAMP ON YOUR SMART TABLE ST230I 20 01032 20 5 Disconnect all cables from the projector 6 Disconnect the vent hose from the back of the projector...

Page 5: ...if it falls off while disconnecting the vent hose Removing the Projector from the Mounting Bracket Before you can replace the projector lamp you must remove the projector from the mounting bracket To...

Page 6: ...e the release latch inside the mounting bracket and then lift it up 3 Using both hands carefully unhook the projector from the projector mounting bracket hooks 4 Remove the projector unit from the cab...

Page 7: ...ructions to replace the lamp To remove and replace the lamp 1 Wait at least 30 minutes for the projector to completely cool down 2 Pull up the outer lamp cover using your finger 3 Remove the outer lam...

Page 8: ...of the lamp module according to your local waste authority 6 Remove the replacement lamp module s packaging CAUTION Do not touch any part of the lamp module except the housing 7 Put the replacement l...

Page 9: ...through the pins located on the stationary mounting bracket 2 Press down on the latch to lock it in place 3 Replace the locking thumbscrews see illustration on page 5 4 Attach the vent hose to the pr...

Page 10: ...3 Press DOWN UP UP LEFT UP DUULU on the remote control to access the service menu 4 Using the remote control select the Lamp Hour Reset option and then press OK Both Lamp Hour values Standard and Econ...

Page 11: ...r projector s image has become misaligned you can adjust the SMART Table surface image using the colored knobs on top of the projector mount To adjust the SMART Table surface image 1 Set the locking s...

Page 12: ...nstallation Guide smarttech com kb 141081 2 3 4 5 1 0 5 20 0 25 0 25 0 25 Orange Purple Blue Yellow Green 09 2011 SMART Technologies ULC All rights reserved The SMART logo SMART Table and smarttech ar...