background image

  6 

The Company does not represent that the service it offers and the product it 

 

provides may not be compromised or circumvented, and that the product will 

 

prevent any personal illness or loss of health by infec on, or otherwise, or that 

 

the product in any case provides accurate warning or protec on. Customer  

 

understand and fully aware that a properly installed and maintained electronic 

 

screening system may only reduce the risk of infec on, illness, or other events 

 

which may occur without such systems and screening, but is not an insurance or 

 

a guarantee or an assurance of preven on, or any assurance that such a 

 

situa on will not occur or that there will be no personal illness or loss to health 

 

as a result of any such situa on.

 

  7 

If the customer has defaulted in payments of any of its dues to the Company, 

 

then this warranty shall stand suspended  ll the  me the customer clears all 

 

his defaults, and such period shall be counted in calcula ng the total period of 

 

warranty. In such circumstances the Company reserves the right to carry out 

 

repair / replacement under this warranty at its own discre on.

  8 

In the event of repairs / replacement of any of the Product or part(s) thereof, 

 

this warranty will therea er con nue and remain in force only for the 

 

unexpired period of the warranty. Moreover the  me taken for repair / 

 

replacement and in-transit whether under the warranty or otherwise shall not 

 

be excluded from the warranty.

  9 

The Company is not liable for any delay in servicing due o reasons beyond the 

 

control of the Company or any of its Authorized Service Centers.

 10  If the Product is given on rent or allowed to be used by any person other than 
 

the first customer without the prior wri en approval of the Company, then this 

 

warranty shall not remain in force and shall lapse with immediate effect.

 11  If the Product is removed from the place where it was installed by the Company 
 

without prior approval of the Company, then the Company shall not be liable to 

 

honor this warranty.

 12  In case a er installa on of the Product, the loca on of the place where the  
 

Product is installed is to be changed, then at least one week before the date of 

 

change, in ma on is to be given to the Company or its Authorized Service 

 

Centre so that the warranty obliga on for the remaining part of the warranty 

 

can be transferred to the new loca on of the first purchaser. in such a case, 

35

Summary of Contents for BIOSLIM

Page 1: ...Pimplas Village Bhiwandi Thane 421302 Maharashtra INDIA Contact 91 7039047042 91 02522 661518 Web www ystems com E mail enquir ystems com SMART I ELECTRONICS SYSTEMS PVT LTD An ISO 9001 2008 certi ed...

Page 2: ...quidofanykindontheunit Whenconnec nguptheBIOSLIMensurethatthemainspowersupplyissafelyisolated Powerupthecontrolleronlywheninstalla oniscomplete As this product is regularly updated we cannot guarantee...

Page 3: ...__ 7 Keypad Menu Details______________________________________________________7 How to Use______________________________________________________________8 Moun ng Plate Details_________________________...

Page 4: ...areclearlyvisibleinallligh ngcondi ons The ngerprintsensorglassmayperiodicallyrequirecleaning usesuitableglasscleaner Never insert objects of any kind into the unit or through the cabinet slots as the...

Page 5: ...ntsbacktotheBioslimdevices Care should be taken iden fying the wires Improper wiring may render permanent damagetothedeviceorpersonalinjury Refer the color code on the Reader to connect the external w...

Page 6: ...c ons keys for programming the device by keypad Other Installa on Details h p www smar systems com So ware html In case you do not have the required power supply included in the package and intends to...

Page 7: ...Card Only UID CARD F PIN UID card pin Card only pin UID only pin Finger only Card nger High Quality Scratch Resistance Op cal Sensor TCP IP weigand Rs485 9600bps Default Max 9999 TFT colour display C...

Page 8: ...h easy to usetouchsensekeypad Descrip on of keys other parts Opera onal keys keys To access keypad func ons to enter UID for veri ca on Scroll keys to select menu a er admin login Back key to go back...

Page 9: ...r iii AddFinger1 acrossUID PressYes PlaceFingerTwice iv AddFinger2 PressYESorNO Enter v Logout A er Admin Login Success Step 2 Veri ca on Process i ShowCard EnterUIDandPlace nger ii ForAuthorizedSwipe...

Page 10: ...hismenuusercaneditthevariousparameterssuchas unitIPaddress subnetmask defaultgateway serverIPaddress etc Userhavetosetvariousparameterssuchas IPAddress Subnetmask Gateway ServerIPAddress LocalportNo P...

Page 11: ...ayed in normal condi on c If System Allow UID by Key Enable Fig C will be displayed d Provides informa on of LAN connec vity 15 39 15 LOGIN SCREEN Home Screen Admin Login 1 2 3 4 5 6 7 8 9 0 Admin ID...

Page 12: ...require 2 Try to set invalid DATE It will not allow to set 3 Add Admin ID 1 Select op on press Enter key 2 Add Admin ID Password 3 Try to Add more than its capacity 1 Admin ID should get added proper...

Page 13: ...e 8 DUA Search Card 3 Enter NEW PIN Press enter properly Pin should be shown 5 Add User Data 1 Enter UID press 2 Select op on from UID Card Finger UID Card only Card Finger Card Only UID CARD F PIN UI...

Page 14: ...ng this op on will see 3 di erent op on 1 Normal 2 Iden fy by Key 3 Auto Iden fy 1 Select any one out of 11 op on 1 Bio Access 2 Bio Access 2RD 3 Bio A n 4 Bio A 2rd 5 Bio A n No chk 6 Bio A No chk2rd...

Page 15: ...ch on display or Card swipe or nger swipe the brightness of display will get to its set value iv Card Digit Display 1 Select any one out of 3 op on 5Digit 8Digit 10Digit Card Number will be displayed...

Page 16: ...3 Reader In Out 4 Fire TAMPER EnDS 5 Set APB En DiS 1 Door Open Time 1 Set Door Open me By default will set to 5sec We can enter the desire door open me and it shows saved message 1 En Dis Share DOTL...

Page 17: ...lete Facility Code 08Delete Door info 09Delete Admin Ids 10Reset System 11Delete Cards Only 12Delete all ngers 13Delete all expt N W 14Ini alize Update Should have show all message properly on display...

Page 18: ...ntroller No Card Bu er Used Card Bu er Bal Card Bu er Trans Bu er Used Trans Bu Bal Trans Bu Templates supp Used Templates Bal Template Serial No Manufacturing Date FW Compile Date Firmware Version Ha...

Page 19: ...enthesecuritylevelisAutoma cSecureand the number of enrolled templates is 500 the actual FAR for iden ca on will be 1 10 000 000 Thesecuritylevelforveri ca onisnotchanged Automa c Level Veri ca on 1 1...

Page 20: ...Server IP Address it is used when MAC security feature is Enable Set Server IP Address where we want to push transac on data using TCP Set Server IP Address where we want to push transac on data usin...

Page 21: ...r ShowcardorEnterUID pressenter PressYES Pressenter SensorgetON PlaceFinger itwillDisplayFinger Addedwith 3 RepeatStepno 2forNumberofUserstoaddedinUnit 4 Nowtocon gdualusergoinUsermenu select DUASearc...

Page 22: ...ls 21 30 0 mm 40 0 mm Pan head self threaded star M3 10 screw in wall 081 mm Pan head self threaded star M3 10 screw in wall 18 0 mm 11 0 mm 11 0 mm 80 0 mm Pan head self threaded star M3 10 screw in...

Page 23: ...22 Notch to Fit the Device Notch to Fit the Device...

Page 24: ...T6 FOR LAN COMMUNICATION Network Switch TCP IP 12V DC Power Supply SLAVE BIOMETRIC READER CAT5e CAT6 FOR LAN COMMUNICATION R Weigand Out EXIT CARD READER STRIKE LATCH ML EXIT SWITCH DOOR MAGNETIC CONT...

Page 25: ...PTION WIRE 1 D GREEN 2 D WHITE PIN PIN DESCRIPTION WIRE 1 TX BLUE 2 TX ORANGE 3 RX GREY 4 V BROWN 5 R YELLOW 6 V BROWN PIN PIN DESCRIPTION WIRE 1 12V RED 2 GND BLACK 3 DO GREEN 4 D1 WHITE 5 BUZZER YEL...

Page 26: ...agement CAT5e CAT6 FOR LAN COMMUNICATION Network Switch TCP IP 12V DC Power Supply ETHERNET A B C D RS 485 POWER WGND OUT 12V GND D D TX TX RX RX V V 12V GND D0 D1 BZ LED TAMP D0 12V GND D0 D1 BZ LED...

Page 27: ...STANDALONE BIOSLIM CONFIGURATION FIRE INTEGRETION PANEL SMARTi So ware BIOSLIM Out HUB EML Lock TCP IP TCP IP 26...

Page 28: ...work WAN asunder Connec ng single controller directly to a PC Using TCP IP CAT5 Network Cable Step1 Usethecrossovernetworkcable withoneendconnectedtotheBiotrakTCP IPport andthe otherendtoyourPCnetwork...

Page 29: ...Refer Con gura on of Biotrak port is default 01234noneedtochange Tes ngtheConnec on Once the con gura on is complete it is recommended that the connec on be tested To testtheconnec onfollowingistheund...

Page 30: ...SuccessfulConnec vity Unsuccessfulconnec vity 29...

Page 31: ...lickStart Run Type command andpress OK Step2 Type telnetipaddressport TheIPAddressshouldre ectthatofyourBioslimunit Note If unsuccessful either Connect failed will be displayed please follow the above...

Page 32: ...it is necessary to place your nger on the ngerprint sensor gently place the last segment of the nger used during enrollment squarely rmly on the ngerprint sensor II Keep nger on ngerprint sensor un l...

Page 33: ...func ons Selectanop onandpressentertogoinIden fymenu InthismenuuserCanset di erenttypesof iden fymodelikenormalmode iden fybykey autosenseetc by usingkeys2 8selectthemodeandsetpressentertosetit Finger...

Page 34: ...nnec onDiagram Con nues Beep Door Force Open ToEnterintoAdminMode searchuser ngerreferkeypadfunc ons Ifuserisaddedthenitwillshowcardnoand ngersenrolled Thestateofyour ngerprintisdry So thesensorcannot...

Page 35: ...y incidental or consequen al losses costs damages expenses or liability incurred by the customer caused due to re intrusion the smokeetc asaresultofanydefectsintheProductsoldoranyof its parts requirin...

Page 36: ...underthiswarrantyatitsowndiscre on 8 Intheeventofrepairs replacementofanyoftheProductorpart s thereof thiswarrantywilltherea ercon nueandremaininforceonlyforthe unexpiredperiodofthewarranty Moreoverth...

Page 37: ...onintheeventofadefectno cedin theProductduringthewarrantyperiod 17 The Company s employees or authorized representa ves have no authority to vary any of he terms of this warranty 18 This Warranty is i...

Page 38: ..._________________ Dateof Purchase ____ ____ ________________ ProductName ___________________ ItemCode ___________________ SerialNo ___________________________ Franchisee Details Name _________________...

Page 39: ...kata 35 Ko ayam 36 Lucknow 37 Ludhiana 38 Madurai 39 Mangalore Udupi 40 Mehsana 41 Mumbai 42 Mysore 43 Nagpur 44 Nasik 45 Navasari 46 Panipat 47 Pa ala 48 Patna 49 Pondicherry 50 Pune 51 Raipur 52 Raj...

Page 40: ...Manufacturing Pharmaceu cal Tourism Hotel Environment please ck relevant Direct Sunlight Air Condi oned Dusty Humid All Func ons working properly Yes No Whether device s are connected to UPS Yes No T...

Page 41: ...Regd O Smart i Electronics Systems Pvt Ltd Bhumi World Pimplas Bhiwandi Thane Maharashtra 421302 INDIA Call 91 02522 661521 500 or email us at service smar systems com...

Reviews: