USER OPERATING INSTRUCTIONS

3715

Electronic Entry Device

OPENING THE LOCK
1. Enter valid six (6) digit combination (factory set to 1-2-3-4-5-6).
2. The lock will confirm a valid combination entry with a double signal.
3. Within four (4) seconds, turn the handle to the open position.
4. Pull door open.
• 

Invalid Combination Entry - Lock will signal three (3) times.

WRONG TRY PENALTY
•  Entry of four (4) consecutive invalid combinations starts a five (5) minute
  delay period.
    - LED flashed red at ten (10) second intervals.
•  At the end of the delay period, two (2) more consecutive invalid combinations
  will restart the additional five (5) minute delay period.

NOTE: Entry will not respond to keystrokes during delay period.

FEATURES
See Manager Instructions for 
additional features.
USER COMBINATION
•  Open Lock
•  Change Combination
WRONG TRY PENALTY
•  Four (4) consecutive invalid combination
  initiates five (5) minute delay period.
LOW BATTERY WARNING
•  Repeated LED flashing and beeping during
  opening indicates battery is low and needs
  immediate replacement.
AUDIO AND VISUAL SIGNAL
•  Double signal - two (2) LED flashes and two
  (2) beeps - indicates entry is valid
  or accepted.
•  Triple signal - three (3) LED flashes and
  three (3) beeps - indicates invalid or
  not accepted.

Reviews: