background image

 

 

 

 

Item 

Description 

Aker 

Part number 

Qty 

F1 

Overload Protection 

SANG MAO 

110V/5A 220V/4A 

F2 

Microswitch of Safety Guard 

ROUZET 

125V/250V 5A 

F3 

Microswitch of Height Adjuster 

Omron 

V-212-1C6 

FR1 

Terminal Block 

GEM 

300V/12V 

IC 

IC Board 

ZEON 

2-MH 29009 

S1 

Emergency Stop Button 

Switchlab 

DC/6A 24V AC/5A 250V 

S2 

Start Button, Timer IC Control 

Microchip 

PAC 16C57-C/P 

M1 

Motor 1/4HP, 1PH, 120V, 50/60Hz  Shiun Jiann 

1/4HP 120V/220V 

Summary of Contents for SL-800A

Page 1: ...Instruction Manual for SL 800A COUNTER TOP MIXER Installation Operation and Maintenance Instructions Revised in December 2009...

Page 2: ...patch from our factory or the date of purchase from one of our approved distributor SHEANG LIEN will replace any defected parts resulted from faulty design material or workmanship SL 800A is a desk to...

Page 3: ...llow lockout procedure before servicing OPERATING INSTRUCTION 1 Lower the bowl and insert ingredient 2 Raise bowl to operating position 3 Select the first speed press start button 4 Do not change gear...

Page 4: ...using cable which is 0 75 or higher and suitable for a 1 4HP motor load The ground wire is fixed to the machine and this connection must be kept intact The mixer MUST be grounded The minimum requirem...

Page 5: ...placed into position by aligning the upside down V cut into the safety guard with the small raised portion on the lip of the bowl Only once the bowl is raised and the guard locked will the machine op...

Page 6: ...ing table lists the recommended capacities of finished weights of regular mixes Although the machine may be capable of mixing larger quantities it will lead to excessive and premature wear and possibl...

Page 7: ...tion CARE OF YOUR MIXER The mixer is designed for minimum user maintenance It may be necessary from time to time to apply a little oil to the rods on which the bowl cradle slides If so use a little fo...

Page 8: ...finish will be adversely affected by the dishwashing chemicals Steady state voltage 0 9 1 1 of nominal voltage Frequency 0 99 1 01 of nominal frequency continuously Avoid exposing to vibration enviro...

Page 9: ...Possible faulty fuse replace fuse Cable damaged or split replace cable Limit switch damaged or faulty replace switch Motor carbon brush worn replace carbon brush Circuit breaker shut off or constantl...

Page 10: ...d ROUZET 125V 250V 5A 1 F3 Microswitch of Height Adjuster Omron V 212 1C6 1 FR1 Terminal Block GEM 300V 12V 1 IC IC Board ZEON 2 MH 29009 1 S1 Emergency Stop Button Switchlab DC 6A 24V AC 5A 250V 1 S2...

Page 11: ...10...

Page 12: ...11...

Page 13: ...M6x16x1 17 1 pinion beater 17T 18 1 ball bearing 6001Z 19 1 planetary gear 56T 20 1 planetary holder 21 1 planetary holder cover 22 1 ball bearing 6002Z 23 1 oil seal 32x17x7 24 1 planetary shaft 25...

Page 14: ...arts Configuration may vary Please specify frequency when ordering 54 1 oil seal 55 1 ball bearing 6203Z 56 1 motor shaft and core Motor Assembly 57 1 motor coil 58 1 pin spring 6x12 Rear Cover of Mot...

Page 15: ...g 92 2 washer M5 93 4 nut stop M5 94 2 screw M5x10 95 1 bowl lift bracket 96 2 bowl lock pins 97 2 spring washer M8 98 2 nut stop M8 99 1 base 100 4 bottom rubber knobs 101 4 washer M8x16 102 4 spring...

Page 16: ...131 1 key way 5x5x14 132 1 third speed gear 36T 133 1 bronze bushing 134 1 second speed gear Parts Configuration may vary 135 1 c ring S15 136 1 ball bearing 6200Z 137 1 shifter yoke Shifter Yoke Ass...

Page 17: ...52_1 1 sleeve for microswitch 152_2 1 nut 153 155 4 nut M3 156 2 screw M5 157 1 microswitch fixture 158 1 microswitch for bowl lifting 159 2 screw M3 160 1 digital control board 161 4 washer M6x1 162...

Reviews: