![SMA SUNNY ISLAND SIC40-MPT Technical Description Download Page 40](http://html1.mh-extra.com/html/sma/sunny-island-sic40-mpt/sunny-island-sic40-mpt_technical-description_1294206040.webp)
Parameter Lists on the Sunny Island
SMA Solar Technology AG
40
SIC40-TEN081110
Technical Description
W867
Sic2ComLoss
Communications loss on the second charge controller for more
than 24 h
W871
Sic3BatShort
Pole of battery connection is reversed or short circuit on the third
charge controller
W872
Sic3BatVtgHi
Battery overvoltage (>65 V) on the third charge controller
W873
Sic3PvVtgHi
Overvoltage of PV generator on the third charge controller
W874
Sic3PvVtgLo
No PV voltage or short circuit on the third charge controller
W875
Sic3TmpLo
Sensor error or undertemperature on the third charge controller
W876
Sic3TmpHi
Device overtemperature on the third charge controller
W877
Sic3ComLoss
Communications loss on the third charge controller for more than
24 h
W881
Sic4BatShort
Pole of battery connection is reversed or short circuit on the fourth
charge controller
W882
Sic4BatVtgHi
Battery overvoltage (>65 V) on the fourth charge controller
W883
Sic4PvVtgHi
Overvoltage of PV generator on the fourth charge controller
W884
Sic4PvVtgLo
No PV voltage or short circuit on the fourth charge controller
W885
Sic4TmpLo
Sensor error or undertemperature on the fourth charge controller
W886
Sic4TmpHi
Device overtemperature on the fourth charge controller
W887
Sic4ComLoss
Communications loss on the fourth charge controller for more
than 24 h
Display no. Display text
Description
Summary of Contents for SUNNY ISLAND SIC40-MPT
Page 2: ......
Page 6: ...SMA Solar Technology AG 6 SIC40 TEN081110 Technical Description...
Page 48: ...Contact SMA Solar Technology AG 48 SIC40 TEN081110 Technical Description...
Page 49: ...SMA Solar Technology AG Contact Technical Description SIC40 TEN081110 49...
Page 50: ...Contact SMA Solar Technology AG 50 SIC40 TEN081110 Technical Description...