Installation
SI4248U Manual
28
Serial Port
The Serial Port is used to communicate with external metering devices such as the Sunny Boy
Control. Use of this port requires that the optional communications Piggy-Back unit be installed.
This port can be configured for RS485 or RS232 formats.
Controller Area Network (CAN)
The CAN connections are used when two Sunny Island 4248U’s are used in split-phase
configuration. Please see the split-phase section of this manual for further details.
Terminal
RS485
RS232
2
A +
RXD
3
not used
TXD
5
GND
GND
7
B -
not used
Table 1-6: Serial Port
Terminal
Function
SHIELD
Communication cable shield
CAN_H
CAN Bus High
C_GND
CAN Bus Common
CAN_L
CAN Bus Low
Table 1-7: Controller Area Network (CAN)