![SMA CLUSTER CONTROLLER User Manual Download Page 58](http://html1.mh-extra.com/html/sma/cluster-controller/cluster-controller_user-manual_1294244058.webp)
5. Select [
Save
].
6. Adjust the strictness of communication monitoring in Sunny Portal if required (see the user
manual of the Cluster Controller in Sunny Portal).
11.4 Setting the Upload Frequency
Delay in data upload possible
To prevent excessive data volume for Sunny Portal at specific times, the Cluster Controller
delays the start of the data upload by up to ten minutes if required.
If a data upload is still in progress and the Cluster Controller is to start a new data upload
(e.g. at a configured time interval of 15 minutes), then the Cluster Controller will not perform
the new data upload and instead transmits the data at the next time interval.
Requirement:
☐ You must already be registered in Sunny Portal (see Section 11.1, page 56).
Procedure:
1. Select the Cluster Controller in the system tree and select the menu
Settings
in the device
menu.
2. Select the parameter group
Sunny Portal > Basic settings
.
3. Select [
Edit
].
4. In the drop-down list
Upload frequency
, select the desired time interval.
Time interval
Explanation
Every 15 minutes
Data upload takes place every 15 minutes.
Hourly
Data upload takes place every 60 minutes.
Daily
Data upload takes place daily at around 1:30 a.m.
5. Select [
Save
].
11.5 Testing the Connection to Sunny Portal
1. Select the Cluster Controller in the system tree and select the menu
Settings
in the device
menu.
2. Select the parameter group
Sunny Portal > Status and Actions
.
3. In the field
Portal connection test
, select [
Execute
].
☑ The Cluster Controller performs the connection test.
OK
is displayed in the field
Result of the
last connection test
.
✖ The connection test has failed?
• Rectify the error (see Section 18.2, page 96).
11 Sunny Portal
SMA Solar Technology AG
User Manual
ClusterController-BA-en-15
58