background image

 

The disposal of the device after lifecycle could damage the environment, need to take it to special 
company for recycling or return to authorized dealer. 

 

The products referred to in this manual conform to the European Community Directives and are 
therefore marked with CE logo. 

 

Keep this device away from children and unauthorized users, the manufacturer will not take 
responsibility for the damage due to any disregard of the information provided in this manual and 
wrong operation. 

 

Before operate the device, pls make sure the fixture is in good housing, ensure pan and tilt can rotate 
in its complete range. 

  --0.5m 

Pls make sure minimal 0.5m distance need to kept between the fixture to any flammable material. 

 

The device can only run with 100-240v voltage, 50/60Hz power, don’t connect to any other wrong 
power. Disconnect the device from main power before open the shield or maintenance. 

 

The device is designed only for indoor usage, pls keep it away from moisture. Do not expose the 
device under the sun or directly to any other lighting source. 

 

 

Never look directly into the projecting lens when the fixture is power on, the light may trigger 
epileptic seizures in photosensitive persons or persons with epilepsy. Especially at beam effect, 
extreme caution and observance of these safety instructions is mandatory. 

 

Don’t put or install the device on a surface that subject to vibration or bumps. 

  Ta=4

5℃

 

The device is supposed to work in the temperate range -15°  C  and  +45°  C, do not use the device 
when the temperate exceed this range. 

 

The lens, shield need to be replaced when obviously broken, never use the device when the shield is 
not completed closed. 

 

Safety I class device, need to be earth connected. 

 

When the fixture is hanged overhead, the safety rope must be fixed to the bottom of the device to 
the appropriate fixing point. 

 

Always carry the device by the handles, do not take the head or arm directly for transportation. 
 

 
2.2 Maintenance 
2.2.1 Operation only allowed to qualified person, damages due to unprofessional operation or remove of any parts 
inside will not be considered in warranty service. There are no serviceable parts inside the device or package, service 
only leaves to authorized dealers. 
2.2.3 Never allow the optical components contact with oil, fat or any other liquid. 
2.2.4 A regular clearance of the device is needed for long-term usage, this is very helpful to maintain the lifetime and 
brightness need to use a soft and lint-free cloth to clean the optical system, fan and air flowing tunnel. 
 
2.2.5. Trouble Shooting 

Problems 

Possible reasons 

Checking or solutions 

Device not power up 

Powercon or power cable damaged 
Faulty power supply 

Change a good power cable to try 
Replace new power supply 

Pan/Tilt error or vibrate 

Faulty Pan/Tilt PCB 
Faulty opto sensor   

Replace PT001 PCB 
Replace opto sensor OP001 

Summary of Contents for B-BYRON

Page 1: ...1 LED BEAM HEAD USERS GUIDE B BYRON ...

Page 2: ...ing mode power supply Optical System Beam angle 7 X Y Pan 630 4 0 sec or 540 3 58 sec Tilt 265 2 8 sec 16 bit resolution Auto repositioning 3 phase motor for crazily fast and quiet movement Features DMX channels 14 22 13 15 Super fast smooth and silent movement RGBW four colors mixing to create vivid saturated and uniform color effect Virtual color wheel for color bounce Full range 0 100 dimmer Va...

Page 3: ...isplay 6 Foot stand 7 Operation button 8 Wireless indicator 9 Mic 10 Left button 11 Enter button 12 Down button 13 Up button 14 Right button 15 Fuse holder 16 Powercon in 17 Power switch 18 Powercon out 19 3 pin DMX out 20 3 pin DMX in 2 Safety and maintenance Information 2 1 Safety Info Before operate this unit please carefully read this users guide and keep if needed in future It s necessary to ...

Page 4: ...y Don t put or install the device on a surface that subject to vibration or bumps Ta 45 The device is supposed to work in the temperate range 15 C and 45 C do not use the device when the temperate exceed this range The lens shield need to be replaced when obviously broken never use the device when the shield is not completed closed Safety I class device need to be earth connected When the fixture ...

Page 5: ... rating which originally installed in the device Step One Unplug power cable from main power Step Two Unscrew the fuse holder out of the housing with a screwdriver Step Three Remove the broken fuse and replace with an exact same type of new fuse Step Four Insert the fuse holder back to the housing and screw tight and reconnect power 3 Installation 3 1 The device could be either put on a solid and ...

Page 6: ... be basic reloaded be program reloaded can be private reloaded Con nect DMX Address XXX DMX address setting Light Max Temperature 80 139 90 176 282 194 Lamp off if temperature continuously over for 5 minutes Lamp Adjust PAN Adjust value of each channels Information Time Info Current XXXX Hours Fixture Life XXXX Hours Fixture boot time Fixture total run time Temperature Near Lamp Temp depends on fi...

Page 7: ... 8bit Basic 16bit User Standard mode Extended mode Basic 8bit mode Basic 16bit mode User program mode Edit User Max Channel XX PAN CH01 Edit users mode Calibration Password Pan XXX XXX Password 050 Calibrate channel value Fixture ID Name Password PID Code Name Password 050 Set PID of RDM Reload Default Basic Reload Program Reload Password Private Reload All Reload ON OFF ON OFF XXX ON OFF ON OFF B...

Page 8: ...annels For example this device has four channel modes 14 22 13 15 if we set the mode at standard 14 channels mode and there are several models need to be independently controlled we just simply address first fixture at 1 and second fixture at 15 third one at 29 etc If the devices have the same address they will behave synchronically DMX addressing is limited don t set the address so high that with...

Page 9: ...robe Rate slow to fast 32 223 Open 224 255 Pulse effect Forward Close 0 31 Strobe Rate slow to fast 32 223 Open 224 255 Pulse effect Reverse Close 0 31 Strobe Rate slow to fast 32 223 Open 224 255 Random Strobe Close 0 31 Strobe Rate slow to fast 32 223 Open 224 255 4 6 Shutter Shutter closed 0 31 No function shutter open 32 63 Strobe effect slow to fast 64 95 No function shutter open 96 127 Pulse...

Page 10: ...130 Red full Green down Blue 0 White 0 131 172 Red full Green 0 Blue up White 0 173 214 Red down Green 0 Blue full White 0 215 255 9 13 8 10 Virtual Color2 Only On Color Bounce Color Bounce Black 0 0 Red 1 1 Green 2 2 Blue 3 3 White 4 4 Red 0 Green up Blue full White 0 5 46 Red 0 Green full Blue down White 0 47 88 Red up Green full Blue 0 White 0 89 130 Red full Green down Blue 0 White 0 131 172 R...

Page 11: ...e if there is any new firmware for this device come out it can be upgraded simply via a software upgrade box no need to change any mechanical parts The upgrade box is not included in the package if need any further assistance pls just contact authorized dealers 6 3 Hibernation the device will enter sleeping mode if activated after a period of disconnecting DMX signal to save the power consumption ...

Page 12: ...ower supply 100 240 V AC 50 60 Hz Power consumption 105W LED 7pcs OSRAM 15W 4in1 leds DMX channels 14 22 13 15 modes Beam angle 7 Luminous flux 2500lumen 15000lux 2 5m Fuse T 2 A 250 V Device dimensions 244x179x322mm Net Weight 6KG ...