background image

6

Insert Soap 

Bottle into the Motor

Assembly

B

Place Soap Bottle into Motor Assembly

A

Remove Soap Bottle Cap.

1

Install Spout

A

Slide Rubber Gasket onto
Brass Shank.

B

Guide Brass Shank and
Sensor Cord through hole
in counter.

Align the Motor Assembly with
the mounting holes and secure
with the 3 stainless steel
screws (included).

2

Mount Motor Assembly

B

Using the Motor Assembly as a template, mark the mounting holes on
wall. Make certain that the Motor Assembly is level.

• When mounting onto a concrete wall, drill holes 1/8” diameter and 11/32” or

more in depth for wall anchors.

• When mounting onto a wood panel, drill pilot holes 3/32” diameter in advance.

C

Position Spout to direct
soap into sink.

C

D

Guide Sensor Cord
through Flange Nut. Screw
Flange Nut onto Brass
Shank and tighten.

A

Refer to the illustration below for mounting hole location.

Note:

Completely remove Clip from

Motor Assembly Outlet.

Note:

The Assembly Box must be mounted

vertically as shown.

Screw Tube Connector onto
Spout Shank and tighten.

5

Attach Tube to Faucet Shank

A

Slide Tube Connector
onto Flexible Tube. Insert
Tube Fitting into end of
Flexible Tube.

B

C

Slide Soap Assembly up over Straight Tube and fit into the Motor
Assembly. Twist Soap Assembly clockwise to lock into place.

SENSOR

RUBBER

GASKET

FLANGE

NUT

SENSOR

CORD

BRASS
SHANK

Choose a location where there will be accessibility to the
unit on the underside of the sink (the Motor and Soap
Container cannot interfere with the water or drain lines).
Before drilling holes in the wall, be sure that no other
pipes or wires exist.

!!! IMPORTANT !!!

MOTOR ASSEMBLY OUTLET

4-1/2”

(114 mm)

13/32” (10 mm)

1-7/64” (28 mm)

TUBE FITTING

TUBE

CONNECTOR

SPOUT

SHANK

TUBE

CONNECTOR

SPOUT

SHANK

SOAP BOTTLE

SOAP BOTTLE

ASSEMBLY

PICK-UP

TUBE

MOTOR

ASSEMBLY

CAP

FLEXIBLE TUBE

C/L

O-RING

O-RING

Important:

Make sure 

O-rings are in place.

Summary of Contents for SJS-1650

Page 1: ...oes not cover the life of the batteries THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER PRIOR TO INSTALLATION New Soap Dispenser Installation Locate position of dispenser using templates shown in rough in diagrams refer to rough in diagrams below Ensure that dispens...

Page 2: ... for mounting hole location Note Completely remove Clip from Motor Assembly Outlet Note The Assembly Box must be mounted vertically as shown Screw Tube Connector onto Spout Shank and tighten 5 Attach Tube to Faucet Shank A Slide Tube Connector onto Flexible Tube Insert Tube Fitting into end of Flexible Tube B C Slide Soap Assembly up over Straight Tube and fit into the Motor Assembly Twist Soap As...

Page 3: ... bottom of Motor Assembly 3 Mount Battery Compartment A B Insert 4 D size batteries in the orientation shown on inside of Compartment Using the Battery Compartment as a template mark the mounting holes on wall Make certain that the Battery Compartment is level Secure with the 3 screws included When mounting onto a concrete wall drill holes 1 8 diameter and 11 32 or more in depth for wall anchors W...

Page 4: ...k soap path for clogging Remove and replace as needed 4 Soap does not dispense when user waves their hands under the spout A Hands must be held steady under the spout for soap to be dispensed 5 Dispenser rotates due to users moving the spout A Tighten the existing flange nut on the shank of the spout under the counter B Add a second flange nut from Sloan to act as a jam nut in conjunction with the...

Reviews: