Connect Sensor Cable and Power
Cable
B
Plug Power Cable (from Battery
Compartment or optional AC
Adapter) into the marked inlet on
the underside of the Motor
Assembly.
A
Plug Sensor Cable (from Spout)
into the marked inlet on the
underside of the Motor Assembly.
Start-up and Operation
A
Press Reset Switch on Motor Assembly to begin the priming cycle and
purge the air out from the Soap Path. The Reset Switch may need to be
pressed again if all the air is not purged out. This procedure must be
followed every time the Soap Bottle is replaced.
B
Place hand under Spout Nozzle.
Sensor will detect hand and
dispense one soap application.
4
Attach Tubes to Motor Assembly
A
Insert male end of Extension
Tube into Motor Assembly and
secure with Clip.
B
Attach Pick-up Tube into
bottom of Motor Assembly.
3
Mount Battery Compartment
A
B
Insert 4 D-size batteries in
the orientation shown on
inside of Compartment.
Using the Battery Compartment as a template, mark
the mounting holes on wall. Make certain that the
Battery Compartment is level. Secure with the 3
screws (included).
• When mounting onto a concrete wall, drill holes 1/8”
diameter and 11/32” or more in depth for wall anchors.
• When mounting onto a wood panel, drill pilot holes 3/32”
diameter in advance.
C
Place Cover over Battery Compartment
and secure with Screw.
Note:
Low Liquid Level yellow
LED in the Sensor Window
will blink when Soap Bottle
needs replacement.
Note:
Low Battery red LED in the Sensor Window
will blink when Batteries need replacement
BATTERY
COMPARTMENT
BATTERY
COMPARTMENT
COVER
SCREW
EXTENSION TUBE
MOTOR ASSEMBLY
CLIP
PICK-UP TUBE
POWER
CABLE
SENSOR
CABLE
RESET
BUTTON
Note:
Before mounting, make certain power
cord will reach Motor Assembly Connection.
O-RING
SENSOR
ADJUSTMENT