Stop).
IMPORTANT: WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT
USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE
COMPONENT OR COUPLING!
Insert Adjustable Tailpiece
into Control Stop. Wet O-ring
seal with water to lubricate.
Secure by hand tightening
Tailpiece Coupling.
Align Flushometer on top of
Vacuum Breaker Flush
Connection and secure by
hand tightening Vacuum
Breaker Coupling.
Align Flushometer Body and
securely tighten Tailpiece
Coupling, Vacuum Breaker
C o upling
and
Spud
Coupling, respectively.
Important Note: U se a
Sloan
A- 50
“ Su per-
Wrench™” or smooth jawed
spud wrench to secure all
couplings. This will eliminate
d am age to c hr ome or
special finish that normally
occurs when slip-joint pliers, pipe wrenches or other “toothed” tools are used.
Step 4 - Install Handle (Figure 6)
Install Handle Assembly to Valve Body and tighten securely.
Step 5 - Flush Out Supply Line (Figure 7)
Shut off Control Stop and remove Flushometer Cover. Lift out the Inside Parts
Assembly. Install Flushometer Cover wrench tight and open Control Stop. Turn
on water supply to flush line of any debris or sediment.
After completion, shut off Control Stop, remove Flushometer Cover and reinstall
Inside Parts Assembly. Install Flushometer Cover wrench tight. Open Control
Stop and activate Flushometer Valve.
Step 6 - Adjust Control Stop (Figure 8)
Adjust Control Stop to meet the flow rate required for the proper cleansing of the
fixture. Open Control Stop COUNTERCLOCKWISE l/2 turn from the closed
position. Activate Flushometer. Adjust Control Stop after each flush until the rate
of flow delivered properly cleanses the fixture.
Important: The Sloan REGAL Flushometer is engineered for quiet operation.
Excessive water flow creates noise, while too little water flow may not satisfy the
needs of the fixture. Proper adjustment is made when:
1. The plumbing fixture is cleansed after each flush without splashing water out
from the lip.
2. A quiet flushing cycle is achieved.
After adjustment: Wrench Tighten Control Stop Cap to Eliminate Vandalism.
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use abrasive or chemical cleaners to clean Flushometers as they may
dull the luster and attack the chrome or special decorative finishes. Use ONLY
soap and water, then wipe dry with clean cloth or towel.
While cleaning the bathroom tile, the Flushometer should be protected from any
splattering of cleaner. Acids and cleaning fluids can discolor or remove chrome
plating.
Figure 8
Figure 7
Figure 6
HANDLE
ASSEMBLY
FLUSHOMETER
BODY
TAILPIECE
COUPLING
CONTROL
STOP
ADJUSTABLE
TAILPIECE
O-RING
VACUUM
BREAKER
COUPLING
VACUUM
BREAKER
FLUSH
CONNECTION
C/L
FIXTURE
C/L
SUPPLY
4-3/4"
(121 mm)
SPUD
COUPLING
G-44
FRICTION
RING
A-31
GASKET