BATTERY REPLACEMENT PROCEDURE
(Step 7A on Page 4)

Sloan OPTIMA Plus

®

EBF-85 and EBF-187 Battery Powered, Sensor

Activated Lavatory faucet models are furnished with four (4) Duracell C-
size Alkaline batteries that provide up to 2 years of operation (at 8000
cycles per month). When the batteries are low and need to be replaced, the
EBF-85 and EBF-187 will signal you. When 256 cycles remain in the unit,
the faucet will BEEP each time it is activated. At this point we recommend
battery replacement. Sloan Valve recommends the use of Duracell MN-
1400 C-size batteries.

To Replace Batteries:

Note:

Water supply to the faucet does not need to be turned off when

replacing batteries.

Loosen security set screw on the Coupling Ring with a 0.05” hex wrench.
Unscrew Battery Compartment Coupling Ring. Remove Battery
Compartment. To ensure proper operation, remove old batteries and insert
four (4) new C-size Alkaline batteries. Check that the orientation of each
battery matches the positive (+) and negative (-) symbols shown at the
bottom of the Battery Compartment. Reattach the Battery Compartment to
the Valve Module by aligning the arrow on the Battery Compartment with
the arrow on the solid tab of the Solenoid Valve Module. Secure by
tightening Battery Compartment Coupling Ring. To deter unauthorized
removal of batteries, use a 0.05” hex wrench to tighten the security set
screw on the Coupling Ring.

Upon installation of the batteries, the EBF-85 and EBF-187 faucet will begin
a new self-calibration procedure (see START UP MODE).

SOLENOID SCREEN FILTER CLEANING
PROCEDURE

A

Unscrew the Filter Cap and remove it from the Solenoid Valve
Housing and carefully pull the Screen Filter with attached rubber
seals out from the Solenoid Valve Housing.

B

Clean the Screen Filter using fresh tap water only. If necessary,
use a small brush to clean. Use caution while cleaning to prevent
damage to the Solenoid Screen Filter. If any Filter components are
damaged, order Filter Replacement Kit EBF-1004-A.

C

Carefully replace the Screen Filter into the groove of the Solenoid
Valve Housing. Examine the Filter Cap O-ring for wear or damage;
replace if necessary.

D

If necessary,
lubricate the Filter
Cap O-ring with
water to keep it in
place in the
groove of the
Filter Cap. Screw
the Filter Cap into
the Solenoid
Valve Housing.

E

Turn on the water supply at the supply stop(s). Activate the faucet
to purge any air from the system lines. Check for leaks and repair
as necessary.

SOLENOID VALVE
HOUSING

SCREEN FILTER

FILTER CAP O-RING

FILTER CAP

IF FILTER COMPONENTS
ARE DAMAGED, ORDER
FILTER REPLACEMENT KIT
— EBF-1004-A

Note:

Before cleaning the Screen Filter, turn off the water supply at the

supply stop(s) and activate the faucet to relieve any pressure in the
system.

Summary of Contents for OPTIMA plus Series

Page 1: ...G IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COMPONENT PART DAMAGE DO NOT USE ANY SEALANT ON COMPRESSION FITTINGS FOR THREADED PIPE FITTINGS DO NOT APPLY SEALANT TO THE FIRST TWO STARTER THREADS FLUSH ALL WATER LINES UNTIL WATER IS CLEAR BEFORE CONNECTING SOLENOID TO SUPPLY STOPS DO NOT INSTALL THE BATTERIES UNTIL THE FAUCET IS COMPLETEL...

Page 2: ...nderside of Trim Plate to prevent Faucet from rotating C Insert Trim Plate Bolts through the 4 inch 102 mm spread deck holes and Faucet Shank through the 1 inch 25 mm minimum diameter deck hole Secure Trim Plate to Deck using the large Plate Washers and Hex Nuts supplied Secure Faucet from below Deck using the Flange Nut supplied ROLL PIN RUBBER FAUCET GASKET COVER PLATE BLACK PLASTIC BASE PLATE D...

Page 3: ...all Bracket in an appropriate location as shown in the Rough In illustrations on Page 2 WALL BRACKET BASE WALL BRACKET SELF TAPPING SCREW PLASTIC ANCHOR WITH SCREW AND WASHER SHOWN B Position Wall Bracket within 20 inches 508 mm from Faucet When installed the Fiber Optic Cable from the Faucet Spout to the Valve Module should have some slack C Use Wall Bracket Base as a template to mark off holes o...

Page 4: ... water line connections VALVE MODULE WALL BRACKET BASE WALL BRACKET SELF TAPPING SCREW 6 Connect Supply Line s from Supply Stop to Solenoid Valve Inlet C Reattach the Battery Compartment to the Valve Module by aligning the arrow on the Battery Compartment with the arrow on the solid tab of the Valve Module D Secure by tightening Battery Compartment Coupling Ring To deter unauthorized removal of ba...

Page 5: ...ration procedure should start automatically after proper electrical connections are made Start Up 8 A Remove Spray Head B Open supply stop s then activate Faucet for 30 seconds by placing hands in front of sensor The Solenoid Valve should click the Valve Module should beep and water should flow from the Spout If this does not occur refer to the Troubleshooting section of this instruction instructi...

Page 6: ... deter unauthorized removal of batteries use a 0 05 hex wrench to tighten the security set screw on the Coupling Ring Upon installation of the batteries the EBF 85 and EBF 187 faucet will begin a new self calibration procedure see START UP MODE SOLENOID SCREEN FILTER CLEANING PROCEDURE A Unscrew the Filter Cap and remove it from the Solenoid Valve Housing and carefully pull the Screen Filter with ...

Page 7: ...ive SOLUTION Replace Solenoid Valve Module Replace EBF 11 A Solenoid Valve Module INDICATOR Module produces audible BEEPs when a target is placed in the detection zone of the Sensor and Solenoid Valve produces an audible CLICK but NO water flows CAUSE Water supply to faucet is not open SOLUTION Open supply stop s completely CAUSE Bak Chek is installed backward SOLUTION Reinstall Bak Chek properly ...

Page 8: ...and Sensor Assembly EBF 187 with CP Metal Throat Plate EBF 1009 A Fiber Optic Sensor Cable Assembly Only replaces EBF 12 A includes lens holder 2 ETF 1021 A 0 5 gpm 1 9 Lpm Spray Head with Key female thread ETF 1022 A 2 2 gpm 8 3 Lpm Aerator Spray Head with Key female thread ETF 1027 A 2 2 gpm 8 3 Lpm Laminar Flow Spray Head female thread ETF 435 Replacement Key ONLY for ETF 1021 A and ETF 1022 A ...

Reviews: