10500 Seymour Ave Franklin Park, IL 60131 | Phone: +1.847.671.4300 / +1.800.982.5839 | Fax: +1.800.447.8329 |
Copyright © 2020 Sloan. All rights reserved.
Page: 7 of 11
Installation Instructions
Code #: 0816884 Draft: 7.0 (10/20)
Operation Instructions AC Power
Figure 5
Fork Lift Guides
Panel, Left
(Removable)
Pull Handle
Waste Tank
Paper Towel Dispenser
Soap Dispenser
Faucet
Panel, Right
(Hinged)
Front View
Note:
Front panel not shown for clarity.
A
A
Water Heater
Drain Pump
On/Off
Water Heater
On/Off
A-A
Right Side View
1. Position the Mobile Handwashing Sink where needed.
2. Lock each caster in place to secure the Mobile Handwashing Sink in place.
a. Press down on the lock lever for each caster until the lever locks into place and the caster no longer
rotates freely.
b. To release the lock lever, press up on each lock lever until the lever locks in the open position and the
caster rotates freely.
3. Connect external water supply in and the waste line out.
4. Plug a 12/3-Prong NEMA L5-20 AMP 125V Power cord (Not supplied) into twist lock AC Power In receptacle
on the rear panel of the Mobile Handwashing Sink, and connect the opposite end to an 110 VAC power
source.
5. Using AC Power.
a. Position the AC / DC Switch to the AC position.
b. Position the Main On/Off Switch in the on position.
c. If using the electric drain pump option, position the drain pump switch in the On position.
6.
When using the Mobile Handwashing Sink for the first time, prime the sensor faucet by moving your hand in
front of the faucet sensor to prime the water lines.
The Mobile Handwashing Sink is ready for use.
7. Drain Waste Tank when above half full.
a. Periodically remove or open an access panel to check the waste tank water level. If the waste tank
water level is more than half full, drain the waste tank.
8. Set all switches to the off position when not in use