Sloan EAF-3X0 Series Installation Instructions Manual Download Page 7

7

OPERATION

As the user’s hands enter the beam’s effective range, the beam is reflected 

back into the sensor receiver and activates the solenoid valve allowing 

water to flow from the faucet. Water will flow until the hands are removed or 

until the faucet reaches its automatic time out setting. 

A

C

D

10 Sec.

10 Sec.

10 Sec.

When assistance is required, please contact Sloan Technical Support at:

Close supply 

stop(s).

B

A30

A10 / A20

A30

A10 / A20

Loosen screw 

with hex wrench 

and remove cap.

• Adjust temperature to desired 

limit

• Adjust screw to meet limit 

setting

Replace cover 

and tighten 

screw with hex 

wrench.

E

Supply Stop

Gasket

Strainer/
Filter

Flex Hose

3/8” Compression Connector

Open 

supply stop(s).

Wait ten (10) 

seconds before 

using faucet.

10 Sec.

F

HOT LIMIT STOP ADJUSTMENT

DO NOT USE

 abrasive or chemical cleaners (including chlorine bleach) to clean faucets that may 

dull the luster and attack chrome or special decorative finishes. Use 

ONLY

 mild soap and water, 

then wipe dry with clean cloth or towel.

While cleaning the bathroom tile, protect the faucet from any splattering of cleaner. Acids and 

cleaning fluids will discolor or remove chrome plating.

1.  Problem  Faucet does not function.

  Cause  Adhesive packaging label affixed over sensor eye.

  Solution  Remove adhesive label from sensor eye.

  Cause  Permanent Off Activated shown by RED flashing  

                     LED.

  Solution   Touch button on sensor window for 2 seconds,  

RED flashing LED will stop and confirmed with 

ORANGE LED.

2.  Problem  Faucet delivers water in an uncontrolled manner.

  Solution  Contact Sloan Technical Support (see below).

3.  Problem   Faucet does not deliver any water with hands in sensor 

range.

 

Indicator  Solenoid valve produces an audible “click.”

  Cause  Water supply stop(s) closed. 

  Solution  Open water supply stop(s).

  Cause  Water supply stop strainer(s) clogged.

 Solution 

 

Turn off water at supply stop(s). Remove, clean 

and reinstall water supply stop strainer(s). Replace 

strainer(s), if required. Turn on water at supply 

stop(s).

 

Indicator   Solenoid valve does not produces an audible “click.”

  Cause  Battery low. 

  Solution  Replace battery (refer to battery replacement).

  Solution  Contact Sloan Technical Support (see below)

4.   Problem    

After removing label water does not flow.

              Use  this  installation  guide  as  a  target  by  placing  it     

                      in front of the sensor (approx. 1-1/2” away) until water    

                      begins  flowing,  then  remove  installation  instruction    

                  from sensor. Water will stop flowing, wait 10 seconds   

                    before using faucet.

5.  Problem   Faucet delivers only a slow flow or dribble when sensor is 

activated.

       

Cause  Water supply stop(s) are partially closeSolution   

                      Completely open water supply stop(s).

  Cause  Water supply stop strainer(s) clogged.

 Solution 

 

Turn off water at supply stop(s). Remove, clean 

and reinstall water supply stop strainer(s). Replace 

strainer(s), if required. Turn on water at supply 

stop(s).

  Cause  Spray head is clogged.

 Solution 

 

Remove, clean, and reinstall spray head. Replace 

spray head, if required.

  Solution  Contact Sloan Technical Support (see below).

6.  Problem   Faucet does not stop delivering water or continues to drip 

after user is no longer detected.

  Solution  Contact Sloan Technical Support (see below).

7.  Problem  LED indicator blinks RED when faucet is in use.

  Cause  Battery low.

  Solution  Replace battery (refer to battery replacement)

8.  Problem   The water temperature is too hot or too cold on a faucet 

connected to hot and cold supply lines.

  Cause  Supply stops are not adjusted properly.

  Solution  Adjust supply stops.

  Cause   For models with integral mixing valve – Mixing valve 

is set improperly for the water temperature desired.

 Solution 

 

Rotate mixing valve handle clockwise to decrease 

water temperature or counterclockwise to increase 

water temperature.

Summary of Contents for EAF-3X0 Series

Page 1: ...ce no later than 30 days after your purchase date In case of a conflict with this summary the terms and conditions set forth in the complete Limited Warranty will prevail pose of resale This warranty does not cover the life of batteries THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY ...

Page 2: ...de View Side View Front View Ø 2 1 8 54 mm 33 5 mm Ø 1 5 16 33 5 mm Min Hole Required 4 3 64 103 mm Spout O ring 13 49 64 350 mm 9 16 UNEF 13 330 mm Long Flex Hose If a connection to separate hot and cold water supplies is desired then a Bak Chek tee fitting or BDM or BDT not supplied must be used prior to connecting to the faucet Tempered Supply Nut Retainer Gasket 45 mm 1 45 mm Max Deck Thicknes...

Page 3: ...ely to the supply stop s A C B Supply Stop Gasket Strainer Filter Flex Hose 3 8 Compression Connector Supply Stop Gasket Strainer Filter Flex Hose 3 8 Compression Connector IMPORTANT Flush dirt debris and sediment from supply line s before connecting flex hose s Note If water flows immediately upon opening supply stops the solenoid is in the open position and will be cycled to the closed position ...

Page 4: ...t Faucet will run for four 4 seconds and the range will automatically adjust to its environment Wait ten 10 seconds after water shuts off before using faucet Activate Faucet and check for leaks If faucet does not function refer to the Troubleshooting section of this instruction manual Optional To fix temperature set lever to the desired position then remove lever and plug hole with cap A A A B B 6...

Page 5: ...ick cover bottom half of sensor with finger wait 2 seconds for Orange light then remove finger When in programming mode each touch of IR Click will produce a quick Orange flash 10 Sec 10 Sec 10 Sec 10 Sec 10 Sec Supply Stop Gasket Strainer Filter Flex Hose 3 8 Compression Connector A30 A10 A20 A30 A10 A20 Function Press Button LED Signal Temporary OFF 2 min 1 1 time for 2 seconds 2 2 times double ...

Page 6: ...10 Sec 4 Sec auto OFF 10 Sec 4 Sec auto OFF 10 Sec 4 Sec 1x 2 Sec auto OFF 10 Sec Deactivate 1x Activate 12HR 2x Activate 24HR Activate 48HR 3x 4x touch touch touch touch touch bottom half 1x 2x 3x 4x 5x 7x 8x 6x factory setting SENSOR RANGE ADJUSTMENT DIAGRAM SENSOR RANGE ADJUSTMENT 12 24 LINE PURGE FEATURE This feature will operate the faucet every 12 or 24 hours since last use or if not used to...

Page 7: ... Open water supply stop s Cause Water supply stop strainer s clogged Solution Turn off water at supply stop s Remove clean and reinstall water supply stop strainer s Replace strainer s if required Turn on water at supply stop s Indicator Solenoid valve does not produces an audible click Cause Battery low Solution Replace battery refer to battery replacement Solution Contact Sloan Technical Support...

Page 8: ...ray Head 5A EAF 1021 A Electronic Sensor 15 Second Shut off with Fixing Clip Kit 0 5 gpm only 5B EAF 1018 A Electronic Sensor 7 Second Shut off with Fixing Clip Kit 1 5 gpm only 6 EAF 1019 A Mixer Handle Assembly and Cartridge Kit 7 EAF 2 Solenoid Valve Cartridge IQ Faucet 8 EAF 1020 A Integral Side Mixer Handle Kit 9 EAF 8 Back Check 2 required for ISM models 10 EAF 1 Faucet Mounting Kit 11 EAF 1...