3
2 - SLIDE GASKET OVER FLEX HOSE(S) AND SECURE
O-RING –
DO NOT REMOVE
FAUCET
GASKET
FAUCET
RETAINER
FLEX
HOSE(S)
NUT
O-RING
FAUCET
GASKET
FAUCET
RETAINER
13 MM
NUT
Remove
before use
Remove
before use
3 - INSTALL STRAINER AND FLEX HOSE ONTO SUPPLY STOP. OPEN SUPPLY STOPS.
Install strainer
and flex hose(s)
onto supply
stop.
Open supply stop(s).
Tighten the flex
hose(s) (with strainer
in place) securely to
the supply stop(s).
A
C
B
Supply Stop
Gasket
Strainer/
Filter
Flex Hose
3/8” Compression Connector
Supply Stop
Gasket
Strainer/
Filter
Flex Hose
3/8” Compression Connector
IMPORTANT: Flush dirt, debris, and sediment from supply line(s) before connecting flex hose(s).
Note:
If water flows immediately upon opening supply stops, the solenoid is in the open position, and
will be cycled to the closed position during the sensor startup sequence in Step 5.
4 - CONNECT TO THE POWER SUPPLY (EAF-300 MODELS ONLY)
Remove