TROUBLESHOOTING
Page 15
PROBLEM
CAUSE
SOLUTION
Control valve fails to
draw brine
Low operating pressure
Check operating pressure; must be higher than 1,4
bar
Drain flow adjuster closed too much
Open drain flow adjuster slowly until unit draws
brine
Plugged injector and/or brine restrictor
Clean injector and/or brine restrictor
Plugged injector filter
Clean injector filter
Restricted drain line
Verify drain line for kinks or restrictions
Restricted brine line
Verify brine line for kinks or restrictions
Leak in brine line
Verify brine line and connections for air leakage
No water in brine tank
Refer to problem “Control valve fails to refill brine
tank”
Backwash solenoid remains open
Verify solenoid membrane and plunger