Sleipner ECU User Manual Download Page 3

 3

1473

8

2021

-

ESI

DECLARATION OF CONFORMITY

Sleipner Motor AS

P.O. Box 519, Arne Svendsensgt. 6-8

N-1612 Fredrikstad, Norway 

Declare that this product with accompanying standard control systems complies with the 

essential health and safety requirements according to:

DIRECTIVE 2013/53/EU

DIRECTIVE 2014/30/EU

DIRECTIVE 2014/35/EU

MC_0020

Contents

• Always keep the boat’s motor running when operating the windlass.

• Always turn off the power to the windlass when it is not operated.

• The anchor must always be secured with security line when windlass is not in use.

• While dropping anchor, do not push the “UP” button until the anchor is resting at the seabed.

• Windlass and accessories must be installed and used in a manner that will not cause damage or injury.

• Personnel qualifi ed for high current installations must carry out or check the installation.

• Do not mount any windlass parts in hazardous environments (I.e. flammable fumes or gasses).

• The control unit is NOT protected from water ingress, it must be installed in a dry area and not exposed for

   water. 

MC_0403

Considerations and Precautions

RESPONSIBILITY OF INSTALLER

The installer must read this document to ensure necessary familiarity with the product before installation. 

Instructions in this document cannot be guaranteed to comply with all international and national regulations. It is the responsibility 

of the installer to follow all applicable international and national regulations when installing Sleipner products.

The recommendations given in this document are guidelines ONLY, and Sleipner strongly recommends that advice is obtained from 

a person familiar with the particular vessel and applicable regulations.

This document contains general installation instructions intended to support experienced installers. If you are not skilled in this 

type of work, please contact a professional installer for assistance.

If required by local regulation, electrical work must be done by a licensed professional.

Health and safety procedures must be followed during installation. 

Faulty installation of Sleipner products will render all warranties given by Sleipner Motor AS.

MC_0038

IMPORTANT NOTICE S-LINK™ SYSTEM

When installing an S-Link™ system DO NOT connect any other control equipment directly to the S-Link™ bus except original Sleipner S-Link™ 

products. Connecting third-party equipment must always be connected through a Sleipner-supplied interface product. Any attempt to directly 

control or connect into the S-Link™ control system without a designated or approved interface will render all warranties and responsibilities 

of all connected Sleipner products. If you are interfacing the S-Link™ bus by agreement with Sleipner through a designated Sleipner supplied 

interface, you are required to install at least one original Sleipner control panel to enable efficient troubleshooting if necessary.

MC_0265

Summary of Contents for ECU

Page 1: ...redrikstad Norway www sleipnergroup com DOCUMENT ID REVISION DATE LANGUAGE To download your language go to www sleipnergroup com 1473 8 K e e p t h i s m a n u a l o n b o a r d 2021 Including Installation For External Control Unit ECU EN U M I M ...

Page 2: ...ng to DIRECTIVE 2013 53 EU DIRECTIVE 2014 30 EU DIRECTIVE 2014 35 EU MC_0020 Contents Considerations and Precautions 3 Features 4 Operations 4 Technical Specifications 4 Operations 5 Configuring Windlass Type 6 Fault codes 6 Troubleshooting 7 Installation Guide Measurements 9 ECU Installation 10 Visual Wiring Diagram 11 12 Spare Parts 13 Product Templates and Additional Resources 13 Warranty State...

Page 3: ...s given in this document are guidelines ONLY and Sleipner strongly recommends that advice is obtained from a person familiar with the particular vessel and applicable regulations This document contains general installation instructions intended to support experienced installers If you are not skilled in this type of work please contact a professional installer for assistance If required by local r...

Page 4: ...sical temperature sensor in the motor Motor Soft Start Reduced speed and force limit after first end stop detection Two end stop points can be detected detected by metal wire spun around the rope at user selected positions Maxi Chain windlass does not include the end stop function Power relays disconnect motor power when the windlass is not in use or if a fault has been detected Delayed start on op...

Page 5: ...Caution When setting anchor it may be diffi cult to control applied load Low drift when releasing the rope boat and rope is not in line can also cause heavy loads on the anchor rollers and fastenings Use a suitable mounting point on the boat Especially under rough conditions inn is pressed and held The windlass starts pulling the anchor The windlass goes from 0 100 speed in 3 sec and continues unti...

Page 6: ...anchor lead MAXI ROPE Configuration set for using a MAXI windlass utilising a rope anchor lead MAXI CHAIN Configuration set for using a MAXI windlass utilising a chain anchor lead MHPP ROPE Configuration set for using a MHPP Midi Hard Pull Parking windlass utilising a rope anchor lead This configuration allows for increased pull after the first end stop This is designed for installations that require a...

Page 7: ...sor and verify that End Stop LED light up Adjust sensor closer to the rope if neccesary Windlass releases anchor but stops immediatly when pressing IN None or Low voltage If the battery is in poor condition it might measure 12 24V when windlass is not in use and still experince a significant voltage drop when the motor starts such voltage dips might be diffcult to measure This type of voltage drops...

Page 8: ...8 1473 8 2021 ESI SLEIPNER AS P O Box 519 N 1612 Fredrikstad Norway www sleipnergroup com DOCUMENT ID REVISION DATE LANGUAGE Installation Guide ...

Page 9: ...ch L ESI Length 190 7 48 L Additional ESI Length 212 8 35 H ESI Height 167 6 6 W ESI Width 59 2 3 W Additional ESI Width 5 0 2 a Distance of attachment holes width 200 7 87 b Distance of attachment holes height 95 3 74 ECU MC_0399 Measurements MG_0330 W a b L L H W ...

Page 10: ...ry surface area Ensure attached cables will protrud downwards NB The unit has mounts that ensures space between the unit and it s mounting surface This to avoid condensation to enter the unit It also ensures proper ventilation of the enclosure 2 Remove the cable cover plate 3 Attached cables Pay attention to assemble the terminal spacers and washers in the correct order Tighten the teminals to max...

Page 11: ...fig B Connec on to control box without Sidepower control cable white to terminal N green to terminal OUT brown to terminal V 4 lead Sidepower control cable Connec on to control box Black to terminal V Blue to terminal N Grey to terminal OUT Red to terminal V Main circuit breaker fuse A Ba ery AUX BAT C Autostop sensor opt Motor Cable size A B and C f total length A B C 10m 25mm2 A B C 10m 35mm2 B A...

Page 12: ...r control cable white to terminal N green to terminal OUT brown to terminal V Connec on to control box Black to terminal V Blue to terminal N Grey to terminal OUT Red to terminal V Visual Wiring Diagram Connecting the motor and battery cables on Maxi Connect the four motor cables to the Terminals masked A1 A2 D1 D2 Connect supply cable from battery negative to the Terminal marked B Connect supply ...

Page 13: ...o the Purchaser at the Warrantor s expense If on the other hand the claim is determined to result from circumstances such as described in section 4 above or a result of wear and tear exceeding that for which the equipment is intended e g commercial use of equipment intended for leisure use the costs for the troubleshooting and repair shall be borne by the Claimant b No refund of the purchase price...

Page 14: ...14 1473 8 2021 ESI MC_0037 Notes ...

Page 15: ...15 1473 8 2021 ESI MC_0037 Notes ...

Page 16: ...naccuracies or omissions it may contain Continuous product improvement may change the product specifications without notice Therefore Sleipner Motor AS can not accept liability for any possible differences between product and document Register your product and learn more at www sleipnergroup com Made in Norway SLEIPNER AS P O Box 519 N 1612 Fredrikstad Norway www sleipnergroup com ...

Reviews: