12
1473
8
2021
-
ESI
MG_0403
Control box
150800
B+
A1
A2
D1
D2
B-
br
bk
con
fi
g
150810
B
AUX
Main circuit
breaker/fuse
BAT
A
+
D E F
B
a�
ery
-
C
A2
A1
D2
D1
Autostop Sensor
(Not applicable for chain)
Motor
Maxi
To change motor direc
�
on:
Change cables D1 and D2 on motor
Cable size A,B,C,D,E and F :
f total length
A+B+C+D+E+F <6m : 25mm2
A+B+C+D+E+F=6-16m : 35mm2
A+B+C+D+E+F>16m : 50mm2
(Altern. control panel)
Control panel
or
Control panel
86-
00002
86-
08950
86-
08955
Opt.
Side-power
remote
receiver
4-lead
Sidepower
control cable
Connec
�o
n to control box
(without Sidepower control cable) :
white to terminal N
green to terminal OUT
brown to terminal V+
Connec
�o
n to control box :
Black to terminal V-
Blue to terminal N
Grey to terminal OUT
Red to terminal V+
Visual Wiring Diagram
Connecting the motor and battery cables on Maxi
- Connect the four motor cables to the Terminals masked A1/A2/D1/D2.
- Connect supply cable from battery negative to the Terminal marked B-.
- Connect supply cable from breaker/fuse to the Terminal marked B+. Connect beaker/fuse to battery main switch.
- Tighten all terminals properly, with a maximum torque of 5Nm. Over-tightening may damage the terminals.
- Leave breaker/fuse disconnected until the installation is completed.
IMPORTANT
If motor runs in the wrong direction, swap cable D1 and D2 on the control unit.