Each thruster system is calculated and set up individually by Sidepower. Please see the enclosed system drawings in the enclosed
unique system manual for the actual installation to get the right hoses and fittings. We advice that you let professionals make the ho
-
ses and fittings. Make sure to clean the hoses internally before assembly. To ensure easy and trouble free connection, apply a small
amount of oil to threads and mating faces before joining. Different kinds of fittings will require different tightening torque to avoid leaka
-
ge. If in doubt, please contact a skilled professional to get the best results.
8
• Place the tank in a position where you have access to connection and inspection points. Ensure that there is enough space to lift out
and replace the filters. Keep in mind to make room for access to the oil filling point.
•
NB: Place the tank high enough to get the oil level above the hydraulic pump. The system requires overpressure in the
pumps suction line.
• Fasten the tank assembly properly.
• Ground the tank electrically to the boats bonding system.
•
Ensure that the tank and other components are thoroughly clean before you start installation of fittings and hoses. Also,
make sure that the fittings and hoses are thoroughly clean (avoid ingress of dirt, water and other contamination).
Tank assembly installation
Hose connections
SYSTEM OVER
VIEW
INST
ALLA
TION
ST
ART UP
USER MANUAL
SER
VICE
TECHNICAL
SPECIFICA
TIONS
PREFITTED JIC
ADAPTORS ARE
AVAILABLE AS AN
OPTION
Cooling water IN (3/4" hose nipple)
Cooling water OUT (3/4" hose nipple)
2x cooling water IN (3/4" hose nipple)
2x cooling water OUT (3/4" hose nipple)
2x feed to pump (2" BSP)
Pressure from pump (1" BSP)
3x drain inlet (1/2" BSP)
3x drain inlet (1/2" BSP)
2x feed to pump (2" BSP)
Pressure from pump (1" BSP)
2x cooling water IN (3/4" hose nipple)
2x cooling water OUT (3/4" hose nipple)
Output to consumers
Output to consumers
NB: Using sharp 90° elbows, T-connections and smaller hoses than recommended in the hydraulic schematic will increase
the resistance in the system and reduce the efficiency/performance.
Using plumbing tape, hemp, similar products or excessive amounts of tread sealant can contaminate the hydraulic oil and
cause blockage inside valves and pumps.
Sidepower Hydraulic System
2.3 - 2006