6
PJC-212
1.0.0- 2010
SERVICE MENU (Systems with one oil tank)
Access SERVICE MENU by pressing MENU button and hold it for 5 Seconds
Shows oil pressure and temperature in the hydraulic tank as well as the serial
number of the panel.
Thrusters can be operated while this display is shown.
Exit Service Menu by pressing
SERVICE MENU (Systems with two oil tanks)
Shows oil pressure and temperature in both hydraulic tanks as well as the serial
number of the panel.
Thrusters can be operated while this display is shown.
Exit Service Menu by pressing
TECHNICAL SPECIFICATIONS,
LCD DISPLAY:
IP 67
Low temp functionality (-40oC)
Mounting bracket
Alarm output max load 200mA
Input voltage 9 - 31V
Max current consumption 110mA