SLEIPNER MOTOR AS SIDE-POWER PJC-322 Installation And User Manual Download Page 2

2

PJC-212

     

1.0.0- 2010

PJC-322 / 321

Control panel with S-link

 CAN-bus connection

Product features 

•  For proportional thruster control with the new S-Link controlled Hydraulic Thrusters
•  Back-lit LCD display with instant feedback

  - 

System status

  - 

Amount of thrust & direction of thrust

  - 

Oil temperature & pressure

•  Interactive multi-language menus
•  CAN-Bus communication with thrusters and accessories
•  Plug & play cables, waterproof and compact connectors
•  Diagnostics via panel

•  Connector for external “buzzer”/loud audible alarms 

DISPLAY IN NORMAL USE:

1 hydraulic tank

Oil Temperature

Thrust power 

and direction

2 hydraulic tanks

Buttons/Indications on screen - left to right:

ON/OFF - DAYTIME/NIGHT Backlight mode - EMERGENCY STOP -  SETTINGS MENU

Oil Temperature,

Port Tank

Oil Temperature,

Starboard Tank

Summary of Contents for SIDE-POWER PJC-322

Page 1: ...N Installasjons og brukermanual Made in Norway Sleipner Motor AS 2010 SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway Tel 47 69 30 00 60 Fax 47 69 30 00 70 w w w s i d e p o w e r c o m sidepo...

Page 2: ...re pressure Interactive multi language menus CAN Bus communication with thrusters and accessories Plug play cables waterproof and compact connectors Diagnostics via panel Connector for external buzzer...

Page 3: ...vated The alarm will be reset automatically when temperature goes below 65oC The thrusters can be run when the oil alarms are active COMMUNICATION ERROR If there is a communication error between the p...

Page 4: ...oling pump can be set to always ON or Automatic When the option Automatic is selected the cooling pump will start when oil tem perature exceeds 50oC and stop when the oil temperature goes below 40oC O...

Page 5: ...backlight Use to switch between daytime or night settings End setting by pressing Adjustments will automatically end after 3 seconds of inactivity 5 5 Automatic OFF time Set time from last activity t...

Page 6: ...ed while this display is shown Exit Service Menu by pressing SERVICE MENU Systems with two oil tanks Shows oil pressure and temperature in both hydraulic tanks as well as the serial number of the pane...

Page 7: ...7 PJC 212 1 0 0 2010 Measurements...

Page 8: ...215 www imnasa com imnasa imnasa com Sweden Sleipner AB Str mstad Tel 46 526 629 50 Fax 46 526 152 95 www sleipnerab se Switzerland Marine Parts Technics AG Volketswil Tel 41 1 997 40 90 Fax 41 1 997...