Sentry

u

TEMP 

ACTIVE

Indicates that the

Fuel Smart HydroStat control is pow-
ered and that the temperature function
is active.

v

TEMP  

HIGH TEMP

Illuminates

when the boiler water temperature
reaches the high limit setting. It will
remain lit until the water temperature falls
10° (see High Limit Differential on page
11). The Fuel Smart HydroStat prevents
burner operation while this LED is on.

w

LWCO 

ACTIVE

Indicates that the low water cut-off (LWCO)

function of the Fuel Smart HydroStat is active. When the
control is installed with a Hydrolevel Electro-Well, this LED will be
on at all times when the control is powered.

IMPORTANT:

If the control is installed with a well other than the

Electro-Well, this LED will not illuminate indicating that the control
is not providing low water cut-off functionality.

LWCO 

LOW WATER

Illuminates if the boiler is in a low water

condition. The Fuel Smart HydroStat will prevent burner operation
during this condition. 

IMPORTANT:

The system must be checked

by a qualified heating professional prior to resuming operation.

WARNING: DO NOT ADD WATER UNTIL THE BOILER
HAS FULLY COOLED.

ECONOMY 

ACTIVE

Indicates that the Thermal Targeting

function is active and the Fuel Smart HydroStat will reduce boiler
temperature to conserve fuel. The Economy feature is activated
using the ECONOMY dial. (See “How Thermal Targeting Works”
on page 4 for more information).

ECONOMY 

TARGET

When the Economy feature is active,

the Fuel Smart HydroStat continually sets target temperatures
below the high limit setting to maximize fuel efficiency. When the

boiler water reaches the target tempera-
ture, the LED illuminates and the burner
will shut down. The boiler water will con-
tinue to circulate and heat the house as
long as the thermostat call continues.
The LED will stay lit until the boiler tem-
perature drops to the differential set point
(see Target Temp Differential on page 4)
at which point the boiler will be allowed to
fire again. NOTE: This LED illuminates
regularly during normal boiler operation.

TEST/SETTINGS

Button

To Test Low Water Cut-Off

: Press and hold the Test/Settings but-

ton for 5 seconds. The display will read LCO.

LWCO TEST

LCO

The red Low Water light should illuminate and the burner circuit
(B1 and B2) should de-energize. NOTE: The control must be
installed with a Hydrolevel Electro-Well for low water cut-off func-
tionality (see page 2 for more details).

To View Current Settings: Press and release the Test/Settings Button
in short intervals to sequentially display the following settings:

HIGH LIMIT SETTING   

HL

q

LOW LIMIT SETTING   

LL

q

ECONOMY SETTING   

ECO

q

CURRENT TARGET TEMPERATURE   

ooo

q

PRE-PURGE SETTING   

Pur

The display will return to boiler temperature (default) if

Test/Settings Button in not pressed for 5 seconds.

ACTIVE

HI TEMP

ACTIVE

LOW W

A

TER

ACTIVE

TARGET

TARGET SETTINGS

❶ ❷ ❸ ❹ ❺ ❻ ❼

TEMP   LWCO   ECONOMY

LED LEGEND and TEST/SETTINGS BUTTON

At initial start up, with the Economy Feature active, the control
establishes a 145°F target temperature. To test the high limit
shut-off function, the Economy Dial must be turned to OFF.
Once tested, restore the Economy setting. If the heating
demand is high, the target will increase over time to satisfy the
heat load.

Thermal Targeting technology analyzes thermostat activity and
continually evaluate how much heat the house requires. When
it is very cold outside, the heat demand is high and the Fuel
Smart HydroStat will raise the boiler s Target temperature to
provide needed heat to the home. When the outside tempera-
ture is milder, the heat demand is lower. During these periods,
the Fuel Smart HydroStat will lower the boiler s Target temper-
ature – saving fuel – while continuing to provide comfort to the
house.

SYSTEM START-UP

HOW THERMAL TARGETING WORKS

NOTE:

Smart DHW Priority : During a call from indirect water heater, the control will de-energize the circulator contacts (C1/C2) to heat
only the indirect tank ensuring an adequate supply of domestic hot water. The control will re-energize the circuator when the
indirect tank is satisfied or if the boiler temperature reaches 170˚F. If the indirect call continues for 45 minutes, the control will
overide the priority function energizing the circulator to provide space heating.

Summary of Contents for S-34

Page 1: ...atest edition The installation must also conform to the additional requirements in this Slant Fin Instruction Book In addition where required by the authority having jurisdic tion the installation mus...

Page 2: ...entry Note Height dimension increases by 1 3 4 when comustible floor kit is used Vent damper may be installed horizontally on all models with use of a vent elbow For more information see figure 2 page...

Page 3: ...it containing electric wires or telephone cables consult local codes or the National Board of Fire Underwriters for specific requirements S 34 2 81 8 145 8 4 33 61 4 190 S 60 3 111 8 175 8 4 37 41 2 2...

Page 4: ...1 NFPA 54 latest edition which will be referred to as the National Fuel Gas Code Local codes apply If a masonry chimney is exposed to the outdoors on one or more sides below the roof line exterior chi...

Page 5: ...e connector to the out door chimney or vent as close to the draft hood as practi cable and without modification of the draft hood or the vent damper See figures 1 2 and 3 2 The inlet size of the vent...

Page 6: ...supply otherwise shock or death can result 1 Power Supply A separately fused circuit is recommended Use a standard 15 amp fuse or breaker and 14 gage conductors in BX cable or conduit Provide disconn...

Page 7: ...ITS EQUIVALENT IGNITER CABLE PILOT GAS PIPE ELECTRIC IGNITION PILOT CIRCULATOR BLOCKED VENT SAFETY SWITCH ROLL OUT SWITCH L2 L1 C1 C2 B1 IGNITION MODULE 24V GND 24V I2 B2 VENT DAMPER HARNESS I1 WIRE...

Page 8: ...8 Sentry Figure 5 Multizoning of Sentry boilers pump zoning system using R845A relay Figure 6 Multizoning of Sentry boiler 2 zone system pump zoning system using R882A B relays...

Page 9: ...9 Sentry Figure 7 Multizoning of Sentry boilers zone valve system using V8043E F zone valves Figure 8 Multizoning zone valve system with indirect water heater DHW Priority using R882A B relay...

Page 10: ...10 Sentry Figure 9 Single zone with indirect water heater DHW Priority using R882A B relay...

Page 11: ...orks below If the heating system is unable to supply needed heat to the house the ECONOMY Dial should be turned to a lower setting example In a three zone house turn the dial to 2 or 1 Conversely if t...

Page 12: ...in the display as Pro 2 Turn the HI TEMP dial to select feature 2 3 Push the Test Settings Button to c for Celsius or F for Fahrenheit 4 Reset LO TEMP and HI TEMP settings to desired temperatures see...

Page 13: ...al to access the Program Mode indicated in the display as Pro 2 Turn the HI TEMP dial to select feature 5 3 Push the Test Settings Button to turn Circulator Hold Off or OFF 4 Reset LO TEMP and HI TEMP...

Page 14: ...ve OFF 2 Fahrenheit or Celsius F c Degrees Fahrenheit Degrees Celsius F 3 LWCO Manual or Automatic Reset A b Automatic Reset Manual Reset A 4 Circulator Options A b C Circulator operation on T TV call...

Page 15: ...oiler operation TEST SETTINGS Button ToTest Low Water Cut Off Press and hold the Test Settings but ton for 5 seconds The display will read LCO LWCO TEST LCO The red Low Water light should illuminate a...

Page 16: ...BURNERS OFF VENT DAMPER CLOSES CIRCULATOR OFF SYSTEM GOES TO STANDBY SPARK GENERATOR MODULE POWERED S8600F OR S8600M IGNITION SPARK STARTS AND PILOT VALVE OPERATOR OPENS S8670E IGNITION SPARK AND PIL...

Page 17: ...larger capacity tank Locate the tank near the boiler as illustrat ed An automatic air vent should be installed in the top of the boiler or air purger See figure 10 B PUMP LOCATION Locating low head p...

Page 18: ...18 Sentry Figure 11 Zoning with circulators optional indirect DHW tank...

Page 19: ...19 Sentry Figure 12 Zoning with zone valves optional indirect DHW tank...

Page 20: ...mell for gas including near the floor If you then smell gas STOP Follow B in the safety information above on this page If you don t smell gas go to next step 8 Turn gas control knob counterclockwise t...

Page 21: ...ce at maximum oper ating temperature after prolonged operation NOTE Observe operation of the pilot burner with appli ance doors in the final operating position Use of a mir ror may be helpful 2 Safety...

Page 22: ...perature is reached the high limit switch should open and the main gas valve should close automatically If the high limit does not operate to close the main gas valve the valve the high limit or the w...

Page 23: ...orizontal run of smokepipe 4 Inadequate chimney or venting system REMEDY 1 Check clean re light See instructions 2 Open gas valve s 3 Close switch 4 Replace fuse 5 Check control Clean contacts or repl...

Page 24: ...er level in boiler Remove and check sensor to ensure metal to metal contact between sensor and inside surface of well Has the event damper opened Control will not fire burner if damper did not fully o...

Page 25: ...y hot water to heating coils in air handling units flow control valves or other devices must be installed to prevent gravity circulation of water in the coils dur ing the cooling cycle IF REPLACEMENT...

Page 26: ...ing after 5 min utes of main burner operation Use the flame of a match or candle or smoke from a cigarette cigar or pipe f After it has been determined that each appliance remaining connected to the c...

Page 27: ...27 Sentry...