background image

Lynx Combi Boiler

8

Removing Jacket Front Panel

1.  Turn black screws 

1

4

turn to open position.

2. Remove front panel.

To replace the panel, reverse procedure. 

INTEGRATED BOILER CONTROL

The integrated boiler control monitors the status of the

room thermostat, high limit switch, low water cutoff (if

installed), water inlet and outlet sensors, flue gas sensor

and flame sensor. It controls the operation of the circula-

tor, combustion blower, gas valve and spark ignitor. The

boiler control also determines the sequence of operation

and timing for pre and post purge periods, trial for ignition

and lock out. 

The control display board provides information on boiler

operation on a mode and temperature display and can be

viewed, programmed and reset with specific push buttons.

Diagnostic information is also provided on the display, to

help determine the cause of boiler failure. 

BOILER CONTROL AND DISPLAY FEATURES

(See Figure 9)

A. BOILER OPERATION STATUS:

“Mode Display”

shows status of boiler operation. (See Table 1).

B. VIEW AND CHANGING TEMPERATURES:

Setting

boiler supply water temperature (See Table 2).

Press “Select” button for viewing following different 
modes on “Mode Display”

1. While “c” is blinking, boiler supply water 

temperature for space heating may be set to
desired temperature. The setting range is between 
90˚ to 185˚F.

2. While “d” is blinking, boiler supply water tempera-

ture to DHW system may be set to desired temper-
ature. The setting range is between 104˚ to 185˚F.

3.

View actual following temperatures on

“Temperature Display”, Press “Select” button
for selection:
a. Supply water temperature – Select #1 on

“Mode Display”.

b. Return water temperature – Select #2 on

“Mode Display”.

c. Flue gas temperature – Select #4 on

“Mode Display”.

d. Outside temperature (if outside sensor is used)

– Select #5 on “Mode Display”.

C.

Display Board Pushbuttons:

1.

Reset

- Used to clear a Lockout Error

(indicated with an “A” in the “Mode Display”)

2.

Select

- Used to scroll through the modes in the

“View and Changing Temperatures” and

“Viewing and Changing System Setting” menus.

3.

Enter

- Used to store values that are changed in

the “View and Changing Temperatures” and  

“Viewing and Changing System Setting” menus.

4.

Up

- Used to increase values in the “View and

Changing Temperatures” and “Viewing and 

Changing System Setting” menus.

5.

Down

- Used to decrease values in the “View and 

Changing Temperatures” and “Viewing and 

Changing System Setting” menus.

“MODE”

DISPLAY

“BURNER STATUS”

STEADY DOT = BURNER ON

BLINKING DOT = BURNER OFF

MODE

“TEMPERATURE”

DISPLAY

(3 DIGITS)

TEMPERATURE

“UP”

PUSH BUTTON

“DOWN”

PUSH BUTTON

“ENTER”

PUSH BUTTON

“SELECT”

PUSH BUTTON

“RESET”

PUSH BUTTON

RESET

SELECT

ENTER

Figure 9. Display Board

Summary of Contents for LX-120CB

Page 1: ...DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas...

Page 2: ...label attached to the boiler For reference we have reproduced those instructions in this manual DO NOT use this boiler if any part has been underwater Immediately call a qualified service technician...

Page 3: ...ich all air for combustion is taken from inside the boiler room Typical direct vent installations are shown on Figures 2 and 3 Non direct vent installation is shown on Figures 4 5 and 6 1 VENTING AND...

Page 4: ...Lynx Combi Boiler 4 Figure 4 Non direct vent sidewall venting...

Page 5: ...Lynx Combi Boiler 5 Figure 5 Non direct vent venting through the roof Figure 6 Non direct vent utilizing an existing chimney as a chase...

Page 6: ...LLER OR SERVICEPERSON TO EXPLAIN AND SHOW YOU Learn what normal pressure to look for If pressure increases from normal the relief valve will open to relieve the pressure Call your service organization...

Page 7: ...our gas supplier call the fire department C Use only your hand to turn the gas supply shut off valve Never use tools If the supply shut off will not turn by hand don t try to repair it call a qualifie...

Page 8: ...ture for space heating may be set to desired temperature The setting range is between 90 to 185 F 2 While d is blinking boiler supply water tempera ture to DHW system may be set to desired temper atur...

Page 9: ...t protection mode Temperature display shows boiler supply water Temp Lockout Alarm condition Temperature Display indicates the lockout code Reset button must be pressed to resume normal operation Erro...

Page 10: ...ote Boiler water supply temperature to DHW heat exchanger could be changed by pressing Up Down button Settable from 104 F to 185 F steps of 1 F The default value is 176 F Press Enter button to store T...

Page 11: ...The reset button must be pressed to clear the error and retry operation The temperature display shows the error code B BLOCKING ERRORS Indicated by an E in the mode display Operation is automatically...

Page 12: ...SLANT FIN CORPORATION Greenvale N Y 11548 Phone 516 484 2600 FAX 516 484 5921 Canada Slant Fin LTD LTEE Mississauga Ontario www slantfin com Slant Fin Corp 2011...

Reviews: