Lynx Combi Boiler
10
Table 2: Viewing and Changing Temperatures
Press “Select” button for viewing different modes on “Mode Display”
MODE
DISPLAY
DESCRIPTION & TEMPERATURE DISPLAY
Space heating supply water temperature could be changed by
pressing “Up/Down” button. Settable from 90˚F to 185˚F
(steps of 1 F). The default value is 176˚F.
Press “Enter” button to store.
(see note)
Boiler water supply temperature to DHW heat exchanger could be
changed by pressing ”Up/Down” button. Settable from 104˚F to
185˚F (steps of 1 F). The default value is 176˚F.
Press “Enter” button to store.
–––––––––––
Temperature display shows actual boiler supply water temperature.
Temperature display shows actual boiler return water temperature.
–––––––––––
Temperature display shows actual flue gas temperature.
Temperature display shows actual outside temperature.
(if outdoor sensor is used)
NOTE:
For space heating mode “0” (boilers not utilizing outdoor sensor))
blinking
blinking
blinking