background image

 

 

 

Figure 1 Elevation View to Satellite 

 

 

Selection of Mounting Surface 

 
The installation must be on a flat horizontal surface. The DMR-200C should not be mounted in an area where 
standing water may occur.  The drain holes in the slots on the bottom of the terminal should not be blocked. 
 
The DMR-200C’s mounting surface must be capable of mechanically supporting the terminal.  If not, a backing 
plate (not supplied) or other suitable reinforcement should be employed. 
 
In some cases, the surface temperature of the mounting platform may exceed the DMR-200C’s maximum 
operating temperature (70C). If this is the case, the DMR-200C needs to be mounted with a thermal barrier 
between it and the mounting surface. 
 
Before drilling any holes, verify that there is enough space to accommodate the bend radius of the DMR-200C 
Cable. The bend radius needs to be measured on the cable supplied with the DMR-200C. 
 

Installation 

 
Once the mounting location has been selected, the DMR-200C needs to be mounted. Select either Bottom 
Connector Mounting (Figure 2) or the Side Connector Mounting (Figure 3) depending on the installation type. 
 
In some cases, the Solution Provider may provide the DMR-200C with a mounting bracket. In this case, the 
following instructions are not required. Refer to the instructions with the mounting bracket.  
 
1) 

Use the Drill Template (see figure 4) to mark the location of the four mounting holes and the connector 
hole.  The orientation of the terminal with a bottom connector is not important.  

2) 

Drill the four mounting holes using the drill with the 5.5 mm bit. 

3) 

Punch or drill the 25 mm hole for the connector.  [Bottom Connector Mount Only] 

4) 

Run two concentric beads (2.0 cm and 3.5 cm from center hole) of waterproof sealing compound 
around the connector hole.  Be careful not to block the drain holes in the slots on the bottom of the 
terminal. [Bottom Connector Mount Only] 

5) 

Secure the terminal in place with the mounting hardware using the screw driver and socket set, 

6) 

Install the mating connector and cable. 

7) 

Wrap the mating connector with waterproof sealing tape [If connector is exposed to elements].

 

 

Summary of Contents for DMR 200C

Page 1: ...n SM200200 BHX XXX Bottom Mount Connector SM200200 SHX XXX Side Mount Connector Shipping Box Contents SkyWave ships the DMR 200C in an individual packaging box with the following parts 1 DMR 200C qty 1 2 Installation Instructions qty 1 This document 3 Mating connector qty 1 Solution Provider may provide a cable instead of the mating connector Tools Required The following tools are required to inst...

Page 2: ...bility of the installer to ensure that the installation is safe and secure Installation Steps Recording Serial Number The DMR 200C s serial number is located in three places a label on the bottom of the terminal a label on the original SkyWave packaging box and electronically inside the terminal The serial number is the DCC004 number followed by six hexadecimal digits This number is a unique ident...

Page 3: ...the DMR 200C needs to be mounted Select either Bottom Connector Mounting Figure 2 or the Side Connector Mounting Figure 3 depending on the installation type In some cases the Solution Provider may provide the DMR 200C with a mounting bracket In this case the following instructions are not required Refer to the instructions with the mounting bracket 1 Use the Drill Template see figure 4 to mark the...

Page 4: ...cially applicable to cases when the RS232 lines are used along with power and ground Verification When the terminal is powered on the ERR LED comes on for 5 seconds and the STAT LED flashes This indicates that the DMR 200C is correctly executing its startup self test sequence After about 5 seconds the ERR LED will turn off and the STAT LED continues flashing at different rates If the ERR LED remai...

Page 5: ... repair and or replacement of any defective components experienced under normal specified operating use and storage conditions at SkyWave s discretion It does not cover any damages caused or associated with the product s misuse Experience with defective products should be communicated to your Solution Provider Shipping of defective product back to the Solution Provider will be in accordance with t...

Page 6: ...Drill Template Plate Thickness 4 0 mm 5 5 mm 4 Places 71 8 mm 25 mm Bottom connector only 143 6 mm Figure 4 DMR 200C Standard Bracket Mounting Plate ...

Reviews: