Figure 2

 

Bottom Connector DMR-200C

 

(SM200200-BXX-XXX)

 

 

 

Figure 3 

Side Connector DMR-200C 

(SM200200-SXX-XXX)

 

 

 

Applying Power 

 
Before connecting the DMR-200C to an external voltage source ensure that the polarity is correct and the 
voltage source is between 9 and 30 VDC. Refer to the Appendix for the connector pin out descriptions. 
 
Always ensure that the ground connection is connected at the same time or before power is applied. This is 
especially applicable to cases when the RS232 lines are used along with power and ground. 
 

Verification 

 
When the terminal is powered on the ERR LED comes on for 5 seconds and the STAT LED flashes. This 
indicates that the DMR-200C is correctly executing its startup self-test sequence. After about 5 seconds, the 
ERR LED will turn off and the STAT LED continues flashing at different rates. If the ERR LED remains on the 
DMR-200C is not functioning correctly. 
 
Any additional verification procedures need to be done in cooperation with the SkyWave Solution Provider as 
these vary depending the installation and the Solution Provider’s application. 
 
 
 
 
 
 
 
 

Summary of Contents for DMR 200C

Page 1: ...n SM200200 BHX XXX Bottom Mount Connector SM200200 SHX XXX Side Mount Connector Shipping Box Contents SkyWave ships the DMR 200C in an individual packaging box with the following parts 1 DMR 200C qty 1 2 Installation Instructions qty 1 This document 3 Mating connector qty 1 Solution Provider may provide a cable instead of the mating connector Tools Required The following tools are required to inst...

Page 2: ...bility of the installer to ensure that the installation is safe and secure Installation Steps Recording Serial Number The DMR 200C s serial number is located in three places a label on the bottom of the terminal a label on the original SkyWave packaging box and electronically inside the terminal The serial number is the DCC004 number followed by six hexadecimal digits This number is a unique ident...

Page 3: ...the DMR 200C needs to be mounted Select either Bottom Connector Mounting Figure 2 or the Side Connector Mounting Figure 3 depending on the installation type In some cases the Solution Provider may provide the DMR 200C with a mounting bracket In this case the following instructions are not required Refer to the instructions with the mounting bracket 1 Use the Drill Template see figure 4 to mark the...

Page 4: ...cially applicable to cases when the RS232 lines are used along with power and ground Verification When the terminal is powered on the ERR LED comes on for 5 seconds and the STAT LED flashes This indicates that the DMR 200C is correctly executing its startup self test sequence After about 5 seconds the ERR LED will turn off and the STAT LED continues flashing at different rates If the ERR LED remai...

Page 5: ... repair and or replacement of any defective components experienced under normal specified operating use and storage conditions at SkyWave s discretion It does not cover any damages caused or associated with the product s misuse Experience with defective products should be communicated to your Solution Provider Shipping of defective product back to the Solution Provider will be in accordance with t...

Page 6: ...Drill Template Plate Thickness 4 0 mm 5 5 mm 4 Places 71 8 mm 25 mm Bottom connector only 143 6 mm Figure 4 DMR 200C Standard Bracket Mounting Plate ...

Reviews: