Thank you for buying this SkyTronic net wire tester. Read this licence thoroughly before using the 
apparatus.  
 

Attention 

-

 

Be sure to use a 9V battery, other voltages might damage the circuit. 

-

 

When you don’t use the tester for a long period of time; remove the battery. 

-

 

Don’t connect this apparatus with a wire which is connected to a mains socket. This might result in  
heavy damage and even death. 

-

 

Never test wiring which is directly connected to an active network. 

-

 

Don’t renew or remove any internal parts. 

-

 

Battery is excluded. 

 

What’s inside the packaging 

-

 

Main unit (signal and terminator) 

-

 

Secondary unit (terminator) 

-

 

2x BNC to RJ45 cable 

-

 This 

manual 

 

How to use 

Plug one end of the cable in the main unit’s sending socket (the one indicated with the red arrow) and 
the other end in the left socket or in the secondary unit’s socket. Now turn the power on by pushing 
and releasing the ‘POWER’ button. The lights will now blink red or green. Check the meaning of the 
indications below. 
 

All green:  ...........................OK, straightwired 
All red:  ..................................OK, crosswired 
Mix or no light:  ................................ miswired 

 
One sequence will take up to two seconds. Now you know how your cable is wired. Push and release 
the ‘POWER’ button again and the apparatus will switch off. 
 
This tester can be used for RJ45 cables and for BNC cables. BNC cables can be connected with the 
tester by connecting them first to the BNC/RJ45 transformer cables. After that, plug it the two RJ45 
ends and you can test the cable the same way you would do with a regular RJ45 cable. 
 

Specifications 

Power supply:  .......................................................................................... 9Vdc / 8mA 
Scan time: ..................................................................................... 2 seconds approx. 
Battery type:  ........................................................ 9V cascade battery (6F – type 22) 
Weight: ................................................................................................................250g 
Size (hxwxd): 

Main unit:  ....................................................................... 27mm x 62mm x 103mm 
Secondary unit:  .............................................................27mm x 30mm x 103mm 

 

 

Specifications and design are subject to changes without prior notice. 

 

Do not attempt to make any repairs yourself. This would invalid your warranty. Do not make any changes to the unit. This would also 
invalid your warranty. The warranty is not applicable in case of accidents or damages caused by inappropriate use or disrespect of the 
warnings contained in this manual. SkyTronic UK cannot be held responsible for personal injuries caused by a disrespect of the safety 
recommendations and warnings. This is also applicable to all damages in whatever form.