background image

ROOM

TEMP

TEMP

SET

ROOM

TEMP

THERMOSTAT FUNCTION

NOTE: The thermo feature operates the appliance whenever the room temperature varies a certain number of degrees from the set 
temperature.  This variation is called the “swing” or temperature differential. This feature lets the appliance turn off and on 2 ºF (1 ºC) 
above or below the set temperature of the room. This is to cushion the number of times the appliance is turned on and off.

THERMO UPDATING FEATURE - TRANSMITTER

When in thermo mode, the transmitter reads the ROOM temperature every 2 minutes, checks the room temperature against the SET 
temperature then sends a signal to the receiver.  

THERMO MODE

THERMO SET

THERMO ON

THERMO OFF

RECEIVER

Install the 4 AA-size batteries supplied with the unit. It is recommended that ALKALINE batteries always be used for this product. 

Be 

sure the batteries are installed with the (+) and (-) ends facing the correct direction.

ON

‡

: will manually turn on appliance.

REMOTE

‡

: will allow use of handheld transmitter. If the system does not respond 

to the transmitter on initial use, check the battery positions in the remote. If that 
does not work, see the SECURITY CODE section. 

OFF

‡

: will disable the remote receiver.

It is suggested that the slide switch be placed in the OFF position if you will 

‡

be away from your home for an extended period of time. 

REMOTE

N

O

F

F

O

LEARN

ADJ

.

Requires 4-AA 1.5V

alkaline batteries

Learning
 button

Frequency
 adjusting
access hole

Remote Receiver

Batt

ery co

ver s

lides o

n/off

Slide

Switch

ON

REMOTE

OFF

The remote receiver has a 3-position slide switch for selecting the mode of operation 

ON/REMOTE/OFF

INSTALLATION

The remote receiver can be either wall-mounted in a standard plastic switch bo

[

 (not metal) or placed on or near the 

¿

replace hearth.  

Preferably, the remote receiver should be wall-mounted in a plastic switch box, as this will protect its electronic components from the 
heat produced by the gas appliance.  The remote receiver should be kept away from temperatures exceeding 130º F.  Battery life is 
also signi

¿

cantly shortened if batteries are exposed to temperatures 130ºF or higher.

Before installation make sure the remote receiver slide switch is in the 

OFF

 position. After installation be sure that the slide switch be 

moved to the 

REMOTE

 position.

MOUNTING THE REMOTE RECEIVER

WALL MOUNT

When wall mounting the remote receiver, longer wires (not included) are required to connect to the gas valve or electronic module. 
These wires must:

Be at least 18 Gauge (AWG)

‡

 

Be no longer than 20’

‡

 

Have no splices

‡

 

Press the 

‡

 

MODE

 key until the LCD screen shows the word “ROOM.” 

(See Thermo Mode graphic)
To adjust set temperature, press and hold the 

‡

 

SET

 key until the de-

sired temperature is reached. The temperature range is 99ºF (32ºC) 
to 45ºF (6ºC). (See Thermo Set graphic)
The LCD screen will display the set temperature for 3 seconds, then 

‡

 

it will 

À

ash the set temperature for 3 seconds. It will default to show 

the room temperature. 
The 

À

ame icon will appear when the control calls for heat. (See 

‡

 

Thermo On graphic). The 

À

ame icon will disappear when the appli-

ance reaches its set temperature. (See Thermo Off graphic).
Press the 

‡

 

MODE

 key to disengage the Thermo Mode. “ROOM” will 

disappear from the LCD screen.

WARNING

This remote control system must be installed exactly as outlined in these instructions.  Read all instructions completely before at-
tempting installation.  Follow instructions carefully during installation.  Any modi

¿

cations of this remote control or any of its compo-

nents will void the warranty and may pose a 

¿

re hazard.

Consult gas appliance manufacturer’s instructions and wiring schematics for proper placement of all wires.  All electronic modules 
are to be wired to manufacturer’s speci

¿

cations.

The following wiring diagrams are for illustration purpose only.  Follow instructions from manufacturer of gas valve and/or electronic 
module for correct wiring procedures.  Improper installation of electric components can cause damage to electronic module, gas 
valve and remote receiver.  

ROOM

TEMP

Allparts Equipment Inc   1-877-475-5660                    www.allpartsinc.com                  October, 2011