DISCHARGING OF LITHIUM BATTERY
Discharging of lithium battery
Number
of
cells
DEC
NiCd Sensitivity
D.Peak Default
-
Batt type
Stop
elapsed
time
INC
+
Battery
voltage
DEC
Start
Enter
-
‘>3 seconds’
INC
+
Discharged
capacity
The value of discharge current on the left can not exceed 1C, and the
value on the right can not be under the voltage recommended by the
manufacturer to avoid deep discharging. Press START/ENTER for
more than 3 seconds to start discharging.
This shows the real-time status of discharging, you can press BATT
TYPE/STOP key to stop discharging.
discharge
current
INC
The processor detects voltage of one cell is too low.
The 4th cell was damaged. The value of voltage may be zero if
disconnection occurs.
The processor monitors voltage of each cell when the battery packs are during its “storage” and
“discharging” process. If voltage of any cell is abnormal, IMAX-B6 will show error message and
terminate the program forcibly. So if there is battery damage or disconnection, you can see the
error message and press INC to know which cell is damaged.
Voltage balancing and monitoring in the discharge process
20