This shows the trigger voltage for automatic charge termination of NiMH
and NiCd battery. The effective value ranges from 5 to 20mV per cell. If the
trigger voltage is set higher, there is a danger of overcharging the battery; if
it is set lower, there is a possibility of premature termination. Please refer
the technical specification of the battery. (NiCd default: 12mV, NiMH default:
7mV)
An optional feature using temperature probe contacting the surface of bat-
tery, the temperature cut-off can be on or off. If it is on, set the maximum tem-
perature at which the charger should allow battery to reach during charge.
Once a battery reaches this temperature during charge, the process will be
terminated to protect the battery.