background image

· 24

B6 Evo

B6 Evo

25 ·

Warning and Error Message

In case of an error,  the screen will display the warning and emit an
audible sound.

E R R O R :
B L A N C E B R E A K

S U P P L Y V O L T
           T O O L O W

S U P P L Y V O L T
          T O O H I G H

E R R O R :
C O N N E C T I O N B R E A K

E R R O R :
W R O N G B A T T T Y P E

E R R O R :
R E V E R S E P O L A R I T Y

E R R O R :
V O L T E R R O R

I N T E R N A L T E M P
T O O H I G H

B A T T T E M P
T O O H I G H

O V E R C H A R G E
C A P A C I T Y L I M I T

O V E R T I M E L I M I T

The battery connection is interrupted.

Incorrect polarity is connected.

The battery capacity charged is higher than the
preset threshold.

Connection of balance socket is interrupted.

The battery cell value differs from the cells detected.

The charging takes longer than the preset
protection time.

Input voltage is lower than 11V.

Wrong battery voltage.

Battery type selected differs from the battery type
detected.

Input voltage is higher than 18V.

Internal temperature goes higher than the preset
threshold.

Battery external temperature goes higher than the
preset protection threshold.

E R R O R :
C E L L N O T M A T C H

System Setting

S Y S T E M        1 / 8
C H G P o w e r :    5 0 W

Sound for button touching

The default charge power is 50W, 
while full charge power is 60W, 
which is available to modify.

Sound for alerts

OFF/ON

It will be operated with the default value of the essential user settings 
when  it  is  powered  on  for  the  first  time.  The  screen  displays  the 
following information in sequence, and the user can change the value 
of the parameter on each screen.
To alter the parameter value, press START/ENTER to make it flash to 
change  the  value  with  INC  or  DEC.  The  value  will  be  stored  by 
pressing START/ENTER once.

ITEM

SELECTION

DESCRIPTION

50W / 60W

OFF / ON

The battery's internal chemical
reaction will cause the temperature
to rise. If the temperature limit is
reached, the process will be
terminated.

The temperature unit is selectable 
between Celsius and Fahrenheit

S Y S T E M        2 / 8
K e y B e e p :       O n

S Y S T E M        3 / 8
B u z z e r :        O n

S Y S T E M        4 / 8
T e m p U n i t :      C

S Y S T E M        5 / 8
S a f e T e m p :    5 0 C

S Y S T E M        6 / 8
I n p u t L o w : 1 1 . 0 V

S Y S T E M        7 / 8
V e r s i o n

S Y S T E M        8 / 8
R e s e t

Low input voltage value.
An error message will prompt when
DC input voltage is lower than the
preset value.

Hardware and firmware version is
displayed.

Reset all setting, and load factory
default setting.

20 C / 68 F - 
80 C / 176 F

C / F

Summary of Contents for iMAX B6 Evo

Page 1: ...without notice 7504 1397 01 This content is subject to change Latest version can be downloaded from www skyrc com If you have any question about this document please contact SkyRC by sending a messag...

Page 2: ...ter maximize their battery performance Pleasure be sure to read the INSTRUCTIONS WARNINGS and SAFETY PRECAUTIONS before the first use Always bear in mind not to mishandle the batteries or battery char...

Page 3: ...ase the parameter value INC Button Go through the menu or increase the parameter value ENTER START Button Confirm the setting or start the process DEC INC Button Check the battery voltage ESC DEC Butt...

Page 4: ...noninflammable and nonconductive surface in a well ventilated area Never place the device on a carpet car seat or similar Keep all the inflammable volatile substances away from the operating area Avoi...

Page 5: ...l l s 1 2 0 V 6 S B A T T P R E S E T 1 5 T y p e P b B A T T P R E S E T 5 5 C o l d O f f P b 1 2 0 0 V 2 0 A C h a r g e ENTER 3s P b C h a r g e 9 8 7 V P b F l o a t C H G 0 1 A C a p 2 9 m A h...

Page 6: ...tion 2 NiMH NiCd or Pb Battery Connection 2 Connecting the battery Always remember to connect in the correct polarity And it is highly recommended to charge your Lithium battery in balance mode for be...

Page 7: ...y Peak charge the battery once twice or three times in cycle automatically Charge Discharge 10 B6 Evo B6 Evo 11 CHG Power battery charging power default charging power is 50W Temp Unit temperature uni...

Page 8: ...BATT PRESET 2 6 Cells 22 2V 6S START ENTER START ENTER ENTER to get the value flash Click INC DEC to select desired Lithium battery type for example LiPo ENTER to get the value flash then click INC D...

Page 9: ...t the Re peak Cycles INC INC INC INC INC INC 14 B6 Evo B6 Evo 15 Lithium Battery Program LiPo LiFe Lilon LiHV BATT PRESET 3 6 Cap Off BATT PRESET 4 6 CHG I 4 0A BATT PRESET 5 6 DISC I 0 4A BATT PRESET...

Page 10: ...SC to step out of the current interface and select the desired charge discharge mode Press and hold START ENTER for seconds to start the program Press ESC STOP to terminate the current process when an...

Page 11: ...to get the value flash Click INC DEC to select DC Out ENTER to confirm To activate and enjoy this function follow below steps ENTER to flicker the option and set the desired output voltage Versatile...

Page 12: ...nect Bluetooth Dongle STOP START V METER ESC DC INPUT 11 18V DATA PORT Bluetooth Dongle is optional and not included in the package SK 600135 CHARGING with SkyCharger Connect the battery to B6 Evo sel...

Page 13: ...r Calibration Warning It is highly recommended NOT to do calibration unless necessary SKYRC will not be liable for the consequences caused by calibration To maximize their battery performance in compe...

Page 14: ...8 CHG Power 50W Sound for button touching The default charge power is 50W while full charge power is 60W which is available to modify Sound for alerts OFF ON It will be operated with the default value...

Page 15: ...get you the highest current automatically How can I detect battery voltage When you are at any interface of the 10 battery program press DEC INC simultaneously to detect the battery voltage When char...

Page 16: ...off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment...

Page 17: ...voltage the voltage at which the battery s charge limit capacity limit is reached The charge process switches from a high current to a low maintenance rate trickle charge at this point From this poin...

Reviews: