CANOPY

Climaglide

®

Mounting instructions carrier system - 10 mm

EN 

Art.N° 80574

Summary of Contents for Climaglide

Page 1: ...CANOPY Climaglide Mounting instructions carrier system 10 mm EN Art N 80574...

Page 2: ...ckwards on a roof always walk forwards Make sure there s enough light in the working zone Low hanging obstacles and falling loads Forbidden to walk under or within a radius of 1 m of a hanging or lift...

Page 3: ...e to your body as possible Parts of more than 25 kg must be lifted with at least 2 persons Personal protective equipment Work clothes safety shoes and helmet are mandatory for everyone Lifeline and ha...

Page 4: ...ND PARTS p 5 DRAWING p 6 USE AND VERSIONS p 7 GENERAL INSTALLATION TIPS p 8 MEASURING YOUR GLASS SLIDING PARTITION p 9 GLASS PLATES SIZES p 10 SPECIFIC INSTALLATION TIPS p 11 16 UPPER RAIL p 11 SIDE P...

Page 5: ...4 glass panels CGT510 Upper rail for 5 glass panels CGB3 Bottom rail for 3 glass panels CGB4 Bottom rail for 4 glass panels CGB5 Bottom rail for 5 glass panels CGL10 Side profile CGPL10 Carrier profil...

Page 6: ...09 2021 6 16 Drawing B1 B4 B5 CGSH sliding lock CGT Upper rail CGL10 side profile CGPL carrier profile CGB bottom rail B3 B1 Upper rail page 11 B2 Side profile with sliding lock page 12 B3 Side profi...

Page 7: ...sliding elements can be parked either to the left L or to the right R With a double system half the sliding elements are set to the left half to the right The bottom rail is pre drilled twice beneath...

Page 8: ...lower rail on the inner floor but 2 mm lower If you install the rail more than 2 mm lower please note that you will need to adjust the glass height In any case always make sure that the bottom rail do...

Page 9: ...parking side against which the glass sliding partition is installed must have at least the same depth Determining the dimensions Measure the width Bp between the posts Measure the height Hg from sill...

Page 10: ...t of the glass is 80 kg where X is the number of panels Below is a calculation example to clarify this Given A single system CG 303 L 10 with a total width Bp of 2975 mm and an Hg of 2150 mm This glas...

Page 11: ...approximately 70 cm and 4 cm from the ends Give each hole a chamfer so that the screw head is sunk Use countersunk screws to secure the profile not supplied In the case of the GX gutter Climalux alway...

Page 12: ...ll the lower rail with 6 mm to 4 cm from the ends and also with a spacing of approximately 70 cm in the indication lines between the outermost tracks Give each hole a chamfer so that the screw head is...

Page 13: ...and down mounting block CGCAL10U CGCAL10D First position the side profile on the parking side and centered above the outermost track Then screw the profile to the stanchion Use short screws for this s...

Page 14: ...make sure the side of the carrier profile is aligned with the side of the glass plate First push the carrier profile manually on the glass as far as possible Tap the carrier profile into the glass pl...

Page 15: ...ermost track The first sliding element is now positioned Check if the sliding element stands perfectly straight and horizontal If not the rail and the upper track must be aligned Repeat this procedure...

Page 16: ...just the position so that the lock enters the opening of the carrier profile Also test the locking positions of the other sliding elements For the seal against rainwater we recommend finishing the low...

Reviews: