Mid Size & Full Size RT’s
Engine Powered
February 2008
SKYJACK, Page 27
Visual and Daily Maintenance Inspections
Section 2 - Operations
Model 71xx
Emergency Main
Power Disconnect
Switch
Battery
Electrical Panel
Motion Control Manifold
Base Control
Switches
Cushion Cylinder
Main Manifold
Brake Manifold
Emergency Lowering
Access Rod
Tilt Sensor
Manifolds
•
Ensure all fittings and hoses are properly
-
tightened and there is no evidence of
hydraulic leakage.
Ensure there are no loose wires or
-
missing fasteners.
Electrical Panel
•
Ensure panel is properly secured and
-
there is no visible damage.
Ensure there are no loose wires or
-
missing fasteners.
Tilt Sensor
•
Ensure tilt sensor is properly
-
secure and there is no visible
damage.
Hydraulic Tank (Model 9250)
•
Ensure hydraulic filler cap is secure.
-
Ensure tank shows no visible damage
-
and no evidence of hydraulic leakage.
Hydraulic Oil (Model 9250)
•
Ensure platform is fully lowered, and then
-
visually inspect the sight gauge located
on the side of the hydraulic oil tank.
The hydraulic oil level should be at or
-
slightly above the top mark of the sight
glass.
Emergency Lowering Access Rod
•
(If Equipped)
Ensure rod is properly secured and there
-
is no visible damage.